Siemens 3VA1050-4ED36-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-4ED36-0DA0 SENTRON MCCB, 50A, 3-Pole, 121kA

MPN3VA1050-4ED36-0DA0

Siemens SENTRON 3VA1 molded case circuit breaker, 3VA1050-4ED36-0DA0, 3-pole, 50 A rated at 40 °C, TM210 thermal-magnetic release, 121 kA breaking capacity at 240 V AC, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1050-4ED36-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10504ED360AA0
3VA1050-4ED36-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.1 W
3VA1050-4ED36-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-4ED36-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-4ED36-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-4ED36-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-4ED36-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1 MCCB for line protection

Thermal derating and breaking capacity by voltage

The 50 A rating holds flat from 40 °C to 50 °C, then derates to 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. Breaking capacity drops with system voltage: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

Integration: DIN-rail footprint and included undervoltage release

Dimensions: 130 mm height, 76.2 mm width (3 in), 70 mm depth (2.76 in). The 3-pole body fits a standard 3-module panel space. No separate UVR module to wire; the release is factory-installed and tested.

Frequently asked questions

What is the breaking capacity of 3VA1050-4ED36-0DA0 at 240 V?

121 kA at 240 V AC. At 415 V it is 75.6 kA, at 440 V it is 52.5 kA, and at 500 V or 690 V it is 11.9 kA.

What does the TM210 release designation mean on this MCCB?

TM210 indicates a thermal-magnetic overcurrent release with a fixed 50 A rating at 40 °C, designed for line protection. It provides inverse-time overload protection (thermal element) and instantaneous short-circuit protection (magnetic element).

Does 3VA1050-4ED36-0DA0 include an undervoltage release?

Yes, it ships with a factory-installed undervoltage release (UVR) that trips the breaker when control voltage drops below the dropout threshold.

Where can I buy 3VA1050-4ED36-0DA0?

This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1050-4ED36-0DA0