Specifications

3VA1050-4ED36-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1050-4ED36-0HA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1050-4ED36-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-4ED36-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-4ED36-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-4ED36-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-4ED36-0HA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1050-4ED36-0HA0 is a SENTRON molded case circuit breaker rated for 50 A continuous current (Iu) across a -25 °C to 70 °C operating range, with full current up to 50 °C and a gentle derating curve above that — 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, 45 A at 70 °C. It breaks up to 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V, so it handles high-fault utility feeds and transformer secondaries without cascading upstream. The TM210 thermal-magnetic release is fixed-trip, line-protection pattern — no adjustable long-time or short-time bands, no ground-fault module, no communication. It's a straight-ahead feeder or branch breaker for panels where selectivity is set by the upstream device, not the breaker itself.

No auxiliary contacts built in (order the 3VA9688-0BL30 auxiliary trip separately if you need remote status). The shunt trip (STL) is included as the auxiliary release design, so a remote trip coil is already on the BOM; no undervoltage release, no phase-failure detection.

Frequently asked questions

Where can I buy 3VA1050-4ED36-0HA0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What are the key ratings for 3VA1050-4ED36-0HA0?

50 A continuous current, 3-pole, 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 11.9 kA at 690 V, with a TM210 thermal-magnetic release.

What compliance documentation does Siemens provide for this MCCB?

The SENTRON 3VA series carries UL, CSA, and IEC certifications typical for molded case circuit breakers; specific RoHS and REACH declarations are available through Siemens documentation channels.

MPN
3VA1050-4ED36-0HA0