Skip to main content
Siemens 3VA1063-2ED32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0AD0 SENTRON MCCB, 63 A, 3-pole, 52.5

MPN3VA1063-2ED32-0AD0

Siemens SENTRON 3VA1063-2ED32-0AD0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, line protection, 52.5 kA at 240 V, 32 kA at 415 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1063-2ED32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-2ED32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-2ED32-0AD0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous current at 40 °C, with the TM210 thermal-magnetic release set for line protection. Its interrupting capacity hits 52.5 kA at 240 V and 32 kA at 415 V — numbers that define the fault-clearing capability at the panel's service entrance or feeder point. The 63 A rating holds flat from 40 °C through 50 °C, then derates to 60.48 A at 55 °C and 56.7 A at 70 °C. Three auxiliary switches (HQ type) are built in, giving status feedback for remote monitoring or PLC inputs. No undervoltage release, no ground-fault module, no communication function — this is a straight thermal-magnetic breaker for basic overcurrent and short-circuit protection.

Frequently asked questions

Does this MCCB include a trip indicator or undervoltage release?

No trip indicator, no undervoltage release, no ground-fault module. It's a basic thermal-magnetic breaker with three auxiliary switches for status feedback.

MPN
3VA1063-2ED32-0AD0