The Siemens 3VA1063-2ED32-0AD0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous current at 40 °C, with the TM210 thermal-magnetic release set for line protection. Its interrupting capacity hits 52.5 kA at 240 V and 32 kA at 415 V — numbers that define the fault-clearing capability at the panel's service entrance or feeder point. The 63 A rating holds flat from 40 °C through 50 °C, then derates to 60.48 A at 55 °C and 56.7 A at 70 °C. Three auxiliary switches (HQ type) are built in, giving status feedback for remote monitoring or PLC inputs. No undervoltage release, no ground-fault module, no communication function — this is a straight thermal-magnetic breaker for basic overcurrent and short-circuit protection.

Siemens 3VA1063-2ED32-0AD0 SENTRON MCCB, 63 A, 3-pole, 52.5
MPN3VA1063-2ED32-0AD0
Siemens SENTRON 3VA1063-2ED32-0AD0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, line protection, 52.5 kA at 240 V, 32 kA at 415 V, IP40 front.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Product version | Line protection |
| Integrated auxiliary / alarm switch ref. | 3VA9988-0AA12 |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Current at 40 °C | 63 A |
| Current at 45 °C | 63 A |
| Current at 50 °C | 63 A |
| Current at 55 °C | 60.48 A |
| Current at 60 °C | 59.22 A |
| Current at 65 °C | 57.96 A |
| Current at 70 °C | 56.7 A |
| Switching capacity class | B |
| Breaking capacity at 240 V | 52.5 kA |
| Breaking capacity at 415 V | 32 kA |
| Breaking capacity at 440 V | 13.6 kA |
| Breaking capacity at 690 V | 7.5 kA |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM210 |
| Parameter | Value |
|---|---|
| Main circuit connection type | lug terminal |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | No |
| Auxiliary CO contacts | 3 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Height | 130 mm |
| Width | 76.2 mm |
| Depth | 70 mm |
Product details
Frequently asked questions
Does this MCCB include a trip indicator or undervoltage release?
No trip indicator, no undervoltage release, no ground-fault module. It's a basic thermal-magnetic breaker with three auxiliary switches for status feedback.
MPN