Skip to main content
Siemens 3VA1063-2ED32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0AF0 SENTRON MCCB, 63 A, 3-Pole, TM210

MPN3VA1063-2ED32-0AF0

Siemens SENTRON 3VA1063-2ED32-0AF0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, 52.5 kA at 240 V, 32 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1063-2ED32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1063-2ED32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Breaking capacity hits 52.5 kA at 240 V, drops to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. The 70 mm depth, 76.2 mm width, and 130 mm height fit the standard SENTRON 3VA footprint, so it swaps into an existing panel layout without re-drilling the mounting holes or re-routing busbars.

The front IP40 rating means it's fine inside a clean enclosure but not for washdown areas — keep it behind a gland plate or cabinet door. Ambient temperature derating is straightforward: full 63 A from 40 °C up to 50 °C, then it steps down to 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. If the circuit needs remote trip or status feedback beyond the auxiliary switch, you'll add those as separate components. The TM210 release has a fixed time delay (tr max. 1 s) for the thermal curve; no field adjustment on the magnetic pickup.

MPN
3VA1063-2ED32-0AF0