Siemens 3VA1063-2ED32-0BA0 SENTRON MCCB, 63 A, 52.5 kA

MPN3VA1063-2ED32-0BA0

Siemens SENTRON 3VA1063-2ED32-0BA0, molded case circuit breaker, 3-pole, 63 A, line protection, TM210 release, 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1063-2ED32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0BA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-2ED32-0BA0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, carrying the full 63 A all the way up to 50 °C before thermal derating kicks in — at 55 °C it's 60.48 A, at 70 °C it's 56.7 A. That 63 A is the Iu rating, so it's the current the breaker will carry without tripping under normal load, not a short-time rating. Breaking capacity drops as voltage climbs: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. This is a line-protection breaker, not a motor-protection or generator breaker. It's sized for feeder and distribution circuits where you need to protect cable and buswork, not a specific motor FLA. The 15 000 mechanical endurance cycles mean it's built for a panel that sees occasional switching, not daily load-break duty.

The auxiliary contact version is "without", so if you need a status contact for the panel PLC, you'll add the separate auxiliary switch (order code 3VA9608-0BB11).

Frequently asked questions

Does 3VA1063-2ED32-0BA0 include an undervoltage release?

Yes, the breaker is built with an integrated undervoltage release (UVR) as standard. The design of the auxiliary release is listed as undervoltage release.

MPN
3VA1063-2ED32-0BA0