Siemens 3VA1063-2ED32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0BH0 SENTRON MCCB, 63 A, 3-Pole, TM210

MPN3VA1063-2ED32-0BH0

Siemens SENTRON 3VA1063-2ED32-0BH0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, line protection, 52.5 kA at 240 V, 32 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1063-2ED32-0BH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-2ED32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0BH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-2ED32-0BH0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous at 40 °C, holding that full rating through 50 °C before a gentle thermal derating curve kicks in — 60.48 A at 55 °C, 56.7 A at 70 °C. That means in a warm panel near a dryer section or drive cabinet, you still get nearly full ampacity without oversizing the frame. Three poles, line-protection version with a TM210 thermal-magnetic trip unit. The interrupting ratings climb to 52.5 kA at 240 V and 32 kA at 415 V — enough headroom for most industrial service-entrance or feeder positions. At 690 V it still clears 7.5 kA. The UVR is the design that drops the breaker when control voltage falls, which keeps a downstream motor from re-accelerating after a dip.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) as standard — the design of the auxiliary release is UVR, so no separate module to order.

MPN
3VA1063-2ED32-0BH0