Specifications

3VA1063-2ED32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1063-2ED32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0DA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this MCCB brings to a panel

The 63 A rating holds flat from 40 °C to 50 °C — no derating needed in a typical warm enclosure — then steps down to 60.48 A at 55 °C and 56.7 A at 70 °C, so a panel builder can plan the fill factor without guessing thermal margin. Breaking capacity hits 52.5 kA at 240 V, drops to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. That 52.5 kA at 240 V covers high-fault utility feeds in North American 240/120 V split-phase or 240 V delta services; the 32 kA at 415 V is the number to check for European 400 V grids. The overcurrent release is a TM210 thermal-magnetic unit — fixed thermal curve, fixed magnetic trip. No electronic adjustment, no communication module, no phase-failure detection. It's a workhorse breaker for straightforward feeder or branch protection where you don't need metering or remote trip.

Footprint and integration

No auxiliary contacts on this variant (order code suffix indicates 'without'), so if you need a status feedback contact, you'll add the separate auxiliary trip module 3VA9608-0BB25.

Frequently asked questions

Does 3VA1063-2ED32-0DA0 have an undervoltage release?

Yes, it includes an undervoltage release (UVR) as standard, so the breaker trips on loss of control voltage.