Skip to main content
Siemens 3VA1063-2ED32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0HC0 SENTRON MCCB, 63 A, 52.5 kA

MPN3VA1063-2ED32-0HC0

Siemens SENTRON 3VA1063-2ED32-0HC0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, 52.5 kA at 240 V, 32 kA at 415 V, shunt trip STL, 2 HQ auxiliary switches, IP40 front, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1063-2ED32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1063-2ED32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-2ED32-0HC0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous at 40 °C, with full current hold through 50 °C — no derating needed in a standard ventilated enclosure. Above that, it steps down to 60.48 A at 55 °C and 56.7 A at 70 °C, so if your panel runs hot near the top of the cabinet, check the thermal curve before sizing. Breaking capacity is the headline: 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. That 52.5 kA figure at 240 V means it handles high-fault scenarios on the secondary side of a 480/277 V step-down transformer or a 240 V distribution bus without cascading upstream — the SCCR headroom is real for a 63 A frame. That's a workhorse choice for motor branch circuits or general distribution where you don't need LSIG selectivity curves; the magnetic pickup is factory-set and non-adjustable. Two HQ auxiliary switches are built in, giving status feedback without an add-on module.

Mounting and integration — fits a standard MCCB footprint

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — the 3VA frame width matches the common 3-pole MCCB footprint on DIN rail or panel-mount. Rated insulation voltage 800 V.

Frequently asked questions

What overcurrent release does this MCCB use?

It uses a TM210 thermal-magnetic release — fixed thermal and magnetic trip settings, no electronic adjustment or LSIG selectivity curves.

Does 3VA1063-2ED32-0HC0 include a shunt trip?

Yes, it has an integrated shunt trip (STL) release for remote tripping, with the trip unit order code 3VA9688-0BL30.

MPN
3VA1063-2ED32-0HC0