Skip to main content
Siemens 3VA1063-2ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0JA0 SENTRON MCCB, 63 A, 52.5 kA

MPN3VA1063-2ED32-0JA0

Siemens SENTRON 3VA1063-2ED32-0JA0, molded case circuit breaker, 3-pole, line protection, TM210 release, shunt trip, 63 A at 40 °C, 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED320AA0
3VA1063-2ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-2ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-2ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0JA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1063-2ED32-0JA0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A at 40 °C through 50 °C, with a slight thermal derating to 58 A at 70 °C. Its 52.5 kA breaking capacity at 240 V AC drops to 32 kA at 415 V and 7.5 kA at 690 V — enough for most distribution panels and motor branch circuits in commercial and light industrial plants.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a 3-pole MCCB that mounts on a DIN rail or panel-mount adapter. The 70 mm depth (2.76 in) is standard for the 3VA frame size; check gland-plate clearance if back-panel wiring is tight. Max power loss is 17.3 W, so ventilation in a sealed enclosure is worth a look if you're grouping several breakers.

For selective coordination downstream of a larger MCCB or upstream of a fused disconnect, the 52.5 kA SCCR at 240 V gives solid fault-clearing headroom. At 415 V the 32 kA rating still covers most industrial service-entrance fault levels.

Frequently asked questions

Where can I buy 3VA1063-2ED32-0JA0 and what is the lead time?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 3VA1063-2ED32-0JA0?

Rated 63 A continuous at 40 °C (derated to 58 A at 70 °C), with a breaking capacity of 52.5 kA at 240 V, 32 kA at 415 V, and 7.5 kA at 690 V. Insulation voltage is 800 V.

Will 3VA1063-2ED32-0JA0 drop into a panel specified for 3VA1110-5ED32-0AA0?

No — the 3VA1110-5ED32-0AA0 is a 100 A frame with different dimensions and a higher continuous rating. The 63 A 3VA1063 shares the same SENTRON 3VA family but has a smaller frame size; it will not physically interchange without re-drilling the mounting holes or changing the bus connection.

What compliance documentation is available for this MCCB?

Standard Siemens SENTRON documentation includes RoHS and REACH compliance declarations, plus UL 489 and IEC 60947-2 certification. Specific certificates are provided with the shipment.

MPN
3VA1063-2ED32-0JA0