Skip to main content
Siemens 3VA1063-2ED32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0JH0 SENTRON MCCB, 63 A, 52.5 kA

MPN3VA1063-2ED32-0JH0

Siemens SENTRON 3VA1063-2ED32-0JH0, molded case circuit breaker, 3-pole, 63 A rated continuous current Iu, 52.5 kA interrupting at 240 V, TM210 thermal-magnetic release, shunt trip STL, 2 aux + 1 alarm switch, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1063-2ED32-0JH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-2ED32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0JH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-2ED32-0JH0 is a SENTRON molded case circuit breaker rated for 63 A continuous at 40 °C, with the same 63 A holding through 50 °C before it starts to taper — 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. That flat thermal curve means you don't lose headroom in a warm panel until you're past 50 °C, which is where most industrial enclosures sit. The interrupting ratings climb with voltage: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. The TM210 overcurrent release is thermal-magnetic — fixed thermal pickup, magnetic trip at 10x In. No communication module, no phase-failure detection, no ground-fault monitoring.

The 3VA1063-2ED32-0JH0 is a 3-pole MCCB with a width of 76.2 mm, depth of 70 mm, and height of 130 mm. That 76.2 mm width is a standard 3-pole frame — it drops into the same DIN-rail or screw-mount footprint as other SENTRON 3VA breakers in the 63 A class.

Frequently asked questions

Where can I buy 3VA1063-2ED32-0JH0 and get a price?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is the closest functional second-source for 3VA1063-2ED32-0JH0?

The 3VA1010-2ED32-0JA0 is a lower-current sibling in the same SENTRON 3VA family. It shares the same 3-pole frame, TM210 release, and shunt trip design, but at a lower continuous rating. The 3VA1063-2ED32-0JH0 carries 63 A; the 3VA1010-2ED32-0JA0 is rated lower. Panel cutout and mounting footprint are the same, so it drops in without rewiring, but the ampacity difference means it only works if the load is below the lower breaker's rating.

What are the key dimensions of 3VA1063-2ED32-0JH0?

Width 76.2 mm, depth 70 mm, height 130 mm. The 76.2 mm width is the standard 3-pole frame size for this SENTRON series.

Will 3VA1063-2ED32-0JH0 drop into a panel specified for 3VA1010-2ED32-0JA0?

Yes — same 3-pole frame width of 76.2 mm, same mounting pattern. The physical swap is direct. The only difference is the continuous current rating: 63 A on the 3VA1063-2ED32-0JH0 versus a lower rating on the 3VA1010-2ED32-0JA0. Verify the load current against the breaker's rating before swapping.

What compliance documentation does Siemens provide for this MCCB?

The part carries the Siemens SENTRON brand and is designed to reference codes per DIN EN 81346-2 (reference code Q). The product designation is molded case circuit breaker. Standard compliance documentation (RoHS, REACH, UL, IEC) is available from Siemens for the 3VA series; specific certification marks are not listed in the spec record for this exact order code.

MPN
3VA1063-2ED32-0JH0