Skip to main content
Siemens 3VA1063-2ED32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED32-0KA0 SENTRON MCCB, 63 A, 52.5 kA

MPN3VA1063-2ED32-0KA0

Siemens SENTRON 3VA1063-2ED32-0KA0, molded case circuit breaker, 3-pole, 63 A, breaking capacity 52.5 kA at 240 V AC, 32 kA at 415 V AC, line protection, TM210 release, shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1063-2ED32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1063-2ED32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-2ED32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED32-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1063-2ED32-0KA0 is a 3-pole molded case circuit breaker rated 63 A continuous current (Iu) across 40 °C to 50 °C ambient — no derating needed in a typical 40 °C panel. Above that, the curve drops: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, 56.7 A at 70 °C. Breaking capacity hits 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. That covers most distribution and motor branch circuits up to 690 V line-to-line. This is the line-protection version (no ground-fault, no phase-failure detection, no communication module). The overcurrent release is a TM210 thermal-magnetic type — fixed thermal and magnetic settings, no electronic adjustment. No auxiliary contacts are included on this variant.

Width 76.2 mm, depth 70 mm, height 130 mm. Front protection IP40. Mechanical endurance 15,000 operations.

Operating limits and storage

Trip indicator is not present on this variant.

Frequently asked questions

Does 3VA1063-2ED32-0KA0 include a shunt trip or auxiliary contacts?

It includes a shunt trip (STL) as the auxiliary release. No auxiliary contacts are included on this variant. The integrated auxiliary trip accessory is order code 3VA9688-0BL33.

MPN