Skip to main content
Siemens 3VA1063-2ED36-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED36-0HA0 SENTRON MCCB, 63A, 52.5kA at 240V

MPN3VA1063-2ED36-0HA0

Siemens SENTRON 3VA1063-2ED36-0HA0, molded case circuit breaker, 3-pole, 63 A rated at 40 °C, breaking capacity 52.5 kA at 240 V, line protection with TM210 release and shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED36-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED360AA0
3VA1063-2ED36-0HA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-2ED36-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-2ED36-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED36-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED36-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED36-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection with shunt trip

It carries a 63 A rating at 40 °C and a rated insulation voltage of 800 V, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) auxiliary release for remote tripping. Breaking capacity reaches 52.5 kA at 240 V AC and 32 kA at 415 V AC, giving it solid fault-interruption headroom for industrial main or subfeed applications where high available fault current is expected.

The breaker holds its full 63 A rating up to 50 °C, then derates gradually to 58 A at 70 °C. Operating ambient range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. Maximum power loss is 17.3 W.

Integration and physical fit

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth. The 3-pole footprint fits standard panel-mount cutouts for SENTRON 3VA breakers. No communication function or undervoltage release is included; the shunt trip is factory-fitted.

Frequently asked questions

How do I get pricing and availability for 3VA1063-2ED36-0HA0?

Submit an RFQ through this listing. The part is sourced to order; current pricing and stock status are confirmed at quote time.

What is the breaking capacity of 3VA1063-2ED36-0HA0 at 415 V?

The breaking capacity at 415 V AC is 32 kA, with higher ratings at lower voltages (52.5 kA at 240 V) and lower ratings at higher voltages (7.5 kA at 690 V).

Does 3VA1063-2ED36-0HA0 include a shunt trip?

Yes, it is equipped with a shunt trip (STL) auxiliary release for remote tripping. It does not include an undervoltage release.

MPN
3VA1063-2ED36-0HA0