Skip to main content
Siemens 3VA1063-2ED36-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED36-0KA0 SENTRON MCCB, 63 A, 3-Pole, 52.5

MPN3VA1063-2ED36-0KA0

Siemens SENTRON 3VA1063-2ED36-0KA0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, shunt trip (STL), line protection, 52.5 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-2ED36-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED360AA0
3VA1063-2ED36-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-2ED36-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-2ED36-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED36-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-2ED36-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED36-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Breaking capacity is 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V — figures that govern its fault-interrupting capability in different supply configurations.

Above that, derating is linear: 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. Maximum power loss is 17.3 W. Dimensions are 70 mm deep, 76.2 mm wide, and 130 mm high — a standard 3-pole MCCB footprint that fits SENTRON panelboards and DIN-rail adapters without extra fillers.

Frequently asked questions

What type of overcurrent release does this MCCB use?

It uses a TM210 thermal-magnetic overcurrent release, which combines a thermal element for overload protection and a magnetic element for short-circuit protection.

MPN
3VA1063-2ED36-0KA0