Skip to main content
Siemens 3VA1063-2ED42-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED42-0HA0 SENTRON MCCB, 63 A, 4-Pole, Shunt

MPN3VA1063-2ED42-0HA0

Siemens SENTRON 3VA1063-2ED42-0HA0, molded case circuit breaker, 4-pole, 63 A at 40 °C, TM210 thermal-magnetic release, shunt trip (STL), line protection, breaking capacity 52.5 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1063-2ED42-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED420AA0

Ratings

3VA1063-2ED42-0HA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W

Protection & Trip Unit

3VA1063-2ED42-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1063-2ED42-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1063-2ED42-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1063-2ED42-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1063-2ED42-0HA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1063-2ED42-0HA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuously at 40 °C without derating. The TM210 thermal-magnetic release handles overload and short-circuit protection in one package — no separate relay needed. A built-in shunt trip (STL) allows remote tripping from a PLC safety output or emergency-stop button, which is useful for coordinated shutdown sequences in a panel.

Breaking capacity by voltage

This MCCB interrupts 52.5 kA at 240 V AC, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The 52.5 kA figure at 240 V covers high-fault utility feeds common in North American 120/240 V split-phase panels; the 32 kA at 415 V suits European 400 V distribution where transformer impedance keeps fault levels lower. The 7.5 kA at 690 V is adequate for industrial 690 V drives and motor control centers — verify the available fault current at the point of installation stays under that threshold.

Thermal derating and ambient limits

Rated current holds flat at 63 A from 40 °C through 50 °C, then drops to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. If the breaker lives in a non-ventilated enclosure near transformers or drives, the 58 A at 70 °C figure is the one to size against — not the 63 A nameplate. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Panel fit and dimensions

The breaker measures 130 mm high, 101.6 mm wide, and 70 mm deep. The 4-pole width (101.6 mm) matches the standard 100 mm MCCB footprint for DIN-rail or panel-mount installation — verify the busbar spacing and enclosure cutout against the existing panel layout before ordering. The 70 mm depth leaves clearance for rear-connected busbars and wiring troughs.

Key specs at a glance

Rated insulation voltage is 800 V. Maximum power loss is 17.3 W. The overcurrent release is TM210 (thermal-magnetic, fixed thermal and magnetic settings). No communication function, no undervoltage release, no ground-fault monitoring. The supplied basic switch is 3VA10632ED420AA0. The product is designed for line protection — not motor protection (no overload class or phase-loss sensitivity).

Frequently asked questions

Where can I buy 3VA1063-2ED42-0HA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing at the time of order.

Will 3VA1063-2ED42-0HA0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?

The 3VA1063-2ED42-0HA0 is a 4-pole, 63 A breaker with a shunt trip; the 3VA1010-2ED32-0JA0 is a different frame size and rating. Physical dimensions and busbar spacing differ — panel fit is not guaranteed without verifying the cutout and connection layout against the existing installation.

What is the breaking capacity of this MCCB at 415 V?

At 415 V AC, the breaking capacity is 32 kA.

MPN
3VA1063-2ED42-0HA0