Siemens 3VA1063-3ED36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-3ED36-0AD0 SENTRON MCCB, 63 A, 3-pole, Line

MPN3VA1063-3ED36-0AD0

Siemens SENTRON 3VA1063-3ED36-0AD0, molded case circuit breaker, 3-pole, 63 A, line protection, TM210 release, 75.6 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1063-3ED36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1063-3ED36-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1063-3ED36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1063-3ED36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1063-3ED36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1063-3ED36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1063-3ED36-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB for line protection — 63 A, 3-pole, TM210 release

The Siemens 3VA1063-3ED36-0AD0 is a SENTRON molded case circuit breaker rated for 63 A continuous current at 40 °C, with a thermal-magnetic TM210 overcurrent release. It is a 3-pole unit configured for line protection, meaning it guards the feeder or downstream distribution against overload and short-circuit faults — not motor or generator duty. The interrupting ratings climb to 75.6 kA at 240 V and 52.5 kA at 415 V, so it clears high-fault currents without cascading upstream in a coordinated panel.

Current derating and thermal limits

The breaker holds its full 63 A rating up to 50 °C ambient. Above that it derates linearly: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. The operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. For a panel that runs hot — say a sealed enclosure near a furnace line — the 55 °C derate to 60.48 A is the figure to size against, not the 63 A nameplate.

Interrupting capacity by voltage

The 3VA1063-3ED36-0AD0 delivers 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. These are the maximum short-circuit currents the breaker can safely interrupt at each voltage level. In a 415 V distribution board with a prospective fault current of 50 kA, this breaker has headroom; at 690 V the 7.5 kA limit means it is suited only for low-fault installations or where upstream current-limiting devices reduce the let-through.

Auxiliary contacts and monitoring

This version ships with three auxiliary switches (HQ type) for remote status indication of the breaker's main contacts. There is no undervoltage release, no shunt trip (voltage trigger), no ground-fault monitoring, no phase-failure detection, and no communication module. The trip indicator is absent, so a blown breaker shows its state only through the auxiliary contacts or visual inspection of the handle. For a PLC input that needs a separate 'breaker tripped' signal, the three switches cover that; if you need undervoltage protection or ground-fault sensing, order a different 3VA variant.

Panel integration and footprint

The breaker measures 76.2 mm wide, 130 mm high, and 70 mm deep. It mounts on a DIN rail or direct panel via the SENTRON base. The IP40 front protection means it is suitable for dry indoor panels — not for washdown or outdoor enclosures without an additional cover. The three auxiliary switches add wiring points on the side; plan for the extra terminal space in the wireway.

Frequently asked questions

Where can I buy 3VA1063-3ED36-0AD0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What are the interrupting ratings of 3VA1063-3ED36-0AD0?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V.

Does 3VA1063-3ED36-0AD0 include an undervoltage release or ground fault monitoring?

No. There is no undervoltage release, no ground-fault monitoring, no shunt trip, no phase-failure detection, and no communication module.