Siemens 3VA1063-3ED36-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-3ED36-0BH0 SENTRON MCCB, 63 A, 3-Pole, 70 mm

MPN3VA1063-3ED36-0BH0

Siemens SENTRON molded case circuit breaker, 3VA1063-3ED36-0BH0, 63 A, 3-pole, line protection, 70 mm depth, with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1063-3ED36-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10633ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1063-3ED36-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.8 W

Protection & Trip Unit

3VA1063-3ED36-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1063-3ED36-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1063-3ED36-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1063-3ED36-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1063-3ED36-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1063-3ED36-0BH0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuously at 40 °C without derating — that holds through 50 °C, then drops 1 A per 5 °C step to 58 A at 70 °C. Three poles, 800 V rated insulation voltage, and a breaking capacity that scales from 75.6 kA at 240 V down to 7.5 kA at 690 V. This is the variant with an integrated undervoltage release (UVR) and a complement of two auxiliary switches plus one trip alarm switch (HQ).

Breaking capacity and selectivity

The interrupting rating tells you where this breaker can be placed in the fault-current hierarchy. At 240 V it clears 75.6 kA — that is a high-capacity main or feeder position. At 415 V it still handles 52.5 kA, enough for most industrial secondary distribution. At 500 V and 690 V it drops to 7.5 kA, which is typical for a downstream branch breaker in a 690 V motor control center. The 800 V rated insulation voltage (Ui) confirms the 690 V interrupting rating is valid at that system voltage. At 19.8 W maximum power loss, panel thermal rise stays manageable — no forced cooling needed in a standard IP54 enclosure for a single breaker, but bank several in a row and you will want to check the aggregate dissipation against the enclosure's thermal budget.

Panel fit and switchgear integration

Dimensions: 130 mm height, 76.2 mm width (3-inch standard), 70 mm depth. That 3-inch wide footprint is the standard SENTRON 3VA fixed-pattern width — it drops into the same mounting cutout as the 3VA1 family. The depth of 70 mm is shallow enough for most 200 mm deep enclosures with room for cable bending radius behind it. The integrated undervoltage release (UVR) is factory-installed — no field add-on module needed. It shares the auxiliary switch slot: two auxiliary switches plus a trip alarm switch (HQ) are already populated, so you have three dry contacts for status feedback to a PLC or annunciator panel. No communication function on this variant — it is a standalone breaker, not a PROFIBUS or Modbus device.

Environmental range

Operates from -25 °C to 70 °C ambient — the current derating above 55 °C is modest (62 A at 55 °C, 58 A at 70 °C). Storage range is -40 °C to 80 °C, which covers most warehouse and shipping conditions. The 70 mm depth figure is the key dimension for panel layout — verify that the enclosure depth plus door clearance accommodates the breaker handle throw and cable exit.

Lifecycle is current — no EOL notice, no phase-out. This is the active catalog number for a line-protection MCCB with UVR and auxiliary switches. No successor number exists because it is the current offering. For BOM continuity, this part is specified into new panels and replacement spares alike.

Frequently asked questions

Where can I buy 3VA1063-3ED36-0BH0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1063-3ED36-0BH0 at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

What is the panel space needed for 3VA1063-3ED36-0BH0?

130 mm height, 76.2 mm (3-inch) width, 70 mm depth. Fits the standard SENTRON 3VA fixed-pattern mounting cutout.

Does 3VA1063-3ED36-0BH0 include an undervoltage release?

Yes, it has a factory-installed undervoltage release (UVR) plus two auxiliary switches and one trip alarm switch (HQ).