Skip to main content
Siemens 3VA1063-3ED36-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-3ED36-0BH0 SENTRON MCCB, 63 A, 3-Pole, 70 mm

MPN3VA1063-3ED36-0BH0

Siemens SENTRON molded case circuit breaker, 3VA1063-3ED36-0BH0, 63 A, 3-pole, line protection, 70 mm depth, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-3ED36-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10633ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1063-3ED36-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.8 W
3VA1063-3ED36-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-3ED36-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-3ED36-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-3ED36-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-3ED36-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1063-3ED36-0BH0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuously at 40 °C without derating — that holds through 50 °C, then drops 1 A per 5 °C step to 58 A at 70 °C. Three poles, 800 V rated insulation voltage, and a breaking capacity that scales from 75.6 kA at 240 V down to 7.5 kA at 690 V.

The interrupting rating tells you where this breaker can be placed in the fault-current hierarchy. At 240 V it clears 75.6 kA — that is a high-capacity main or feeder position. At 415 V it still handles 52.5 kA, enough for most industrial secondary distribution. At 500 V and 690 V it drops to 7.5 kA, which is typical for a downstream branch breaker in a 690 V motor control center. At 19.8 W maximum power loss, panel thermal rise stays manageable — no forced cooling needed in a standard IP54 enclosure for a single breaker, but bank several in a row and you will want to check the aggregate dissipation against the enclosure's thermal budget.

Panel fit and switchgear integration

Dimensions: 130 mm height, 76.2 mm width (3-inch standard), 70 mm depth. That 3-inch wide footprint is the standard SENTRON 3VA fixed-pattern width — it drops into the same mounting cutout as the 3VA1 family. The integrated undervoltage release (UVR) is factory-installed — no field add-on module needed.

Environmental range

Operates from -25 °C to 70 °C ambient — the current derating above 55 °C is modest (62 A at 55 °C, 58 A at 70 °C). The 70 mm depth figure is the key dimension for panel layout — verify that the enclosure depth plus door clearance accommodates the breaker handle throw and cable exit.

Lifecycle is current — no EOL notice, no phase-out. This is the active catalog number for a line-protection MCCB with UVR and auxiliary switches. No successor number exists because it is the current offering. For BOM continuity, this part is specified into new panels and replacement spares alike.

Frequently asked questions

Where can I buy 3VA1063-3ED36-0BH0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1063-3ED36-0BH0 at different voltages?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

What is the panel space needed for 3VA1063-3ED36-0BH0?

130 mm height, 76.2 mm (3-inch) width, 70 mm depth. Fits the standard SENTRON 3VA fixed-pattern mounting cutout.

Does 3VA1063-3ED36-0BH0 include an undervoltage release?

Yes, it has a factory-installed undervoltage release (UVR) plus two auxiliary switches and one trip alarm switch (HQ).

MPN
3VA1063-3ED36-0BH0