Siemens 3VA1063-3ED42-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-3ED42-0DH0 Circuit Breaker, 63A, 25kA @ 415V

MPN3VA1063-3ED42-0DH0

Siemens 3VA1 IEC frame 100 circuit breaker, breaking capacity class N, 63A, 25kA @ 415V, 4-pole, TM210 line protection, undervoltage release 208-230V AC, 2 auxiliary switches HQ, 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Circuit breaker 3VA1, 63 A, 25 kA — what the ratings mean for the panel

The Siemens 3VA1063-3ED42-0DH0 is a 4-pole IEC frame 100 molded-case circuit breaker rated 63 A continuous (Ir fixed at 63 A) with a TM210 thermal-magnetic trip unit — the thermal element handles overloads, the magnetic element (fixed at 10 x In, so 630 A) clears short-circuits. Breaking capacity class N means it can interrupt 25 kA at 415 V AC, which covers most industrial distribution panels fed from a 500 kVA or smaller transformer; above that you'd step to class S or H for higher SCCR. The undervoltage release (UVR) set for 208–230 V AC 50/60 Hz drops the breaker on loss of control voltage — common in safety circuits or remote shunt-trip applications. Two HQ auxiliary switches and one HQ trip alarm switch provide status feedback to a PLC or annunciator panel.

Deployment context — panel integration

The 3VA1 frame mounts on a DIN rail or panel-mount adapter inside a standard IP54 or higher enclosure. The nut keeper kit (included) secures the breaker to the mounting plate without loose hardware — a time-saver during panel assembly. The UVR coil draws power from the control circuit (208–230 V AC); verify the control transformer is sized to handle the inrush. Auxiliary and alarm switches are pre-wired to terminal blocks on the breaker face, simplifying the wiring to the PLC input card.

Frequently asked questions

Where can I buy 3VA1063-3ED42-0DH0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1063-3ED42-0DH0?

The breaking capacity is 25 kA at 415 V AC (class N), which is suitable for most industrial distribution panels fed from a transformer up to about 500 kVA.

What does the TM210 trip unit mean?

TM210 is a thermal-magnetic trip unit: the thermal element provides overload protection (Ir fixed at 63 A), and the magnetic element provides fixed short-circuit protection at 10 x In (630 A).

MPN
3VA1063-3ED42-0DH0