Skip to main content
Siemens 3VA1063-3ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-3ED46-0AA0 SENTRON MCCB, 63 A, 4-Pole, TM210

MPN3VA1063-3ED46-0AA0
Active

Siemens SENTRON 3VA1063-3ED46-0AA0, molded case circuit breaker, 4-pole, 63 A at 40 °C, TM210 thermal-magnetic trip, breaking capacity 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-3ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1063-3ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-3ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-3ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-3ED46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-3ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-3ED46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

It is a 4-pole unit, meaning it switches all three phases and the neutral, sized for main feeder or large sub-feed protection in a distribution panel. Breaking capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 500 V and 690 V — so at common 400 V class supply it clears 52.5 kA fault current, which covers most industrial service-entrance and feeder applications. The TM210 trip gives fixed thermal and magnetic settings; no electronic adjustment or communication function here.

Four-pole width means it occupies about 4 inches of panel width per unit. Rated insulation voltage 800 V, so it suits 690 V systems with margin. Operating temperature range -25 °C to 70 °C; current derates above 55 °C — at 65 °C it still carries 60 A, at 70 °C it drops to 58 A. That matters if the breaker sits near transformers or drives in a warm cabinet.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

52.5 kA at 415 V, which covers most industrial 400 V class feeder applications.

Where can I buy 3VA1063-3ED46-0AA0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Will 3VA1063-3ED46-0AA0 drop into a panel specified around 3VA1110-5ED36-0AC0?

Not a direct mechanical or electrical drop-in — the 3VA1110-5ED36-0AC0 is a higher-rated frame (100 A class) with different dimensions and trip characteristics. Verify panel cutout and bus bar spacing before substituting.

What compliance documentation does this breaker carry?

As a SENTRON series MCCB it is designed to meet IEC 60947-2 and UL 489 standards; specific RoHS/REACH declarations are available from the manufacturer on request.

MPN
3VA1063-3ED46-0AA0