Skip to main content
Siemens 3VA1063-4ED32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-4ED32-0KA0 SENTRON MCCB, 63 A, 121 kA at 240

MPN3VA1063-4ED32-0KA0

Siemens SENTRON 3VA1063-4ED32-0KA0, 3-pole molded case circuit breaker, 63 A rated continuous current, 121 kA breaking capacity at 240 V AC, line protection with TM210 thermal-magnetic release and shunt trip (STL).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-4ED32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1063-4ED32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1063-4ED32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-4ED32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-4ED32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-4ED32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-4ED32-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1063-4ED32-0KA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release and an integrated shunt trip (STL) for remote tripping. Breaking capacity reaches 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V — figures that govern selectivity coordination in high-fault distribution panels.

At 415 V, the 75.6 kA interrupting rating positions this MCCB for main or feeder duty in installations where the prospective short-circuit current exceeds what a standard 50 kA or 65 kA breaker can handle — common in industrial substations or near large transformers. The 121 kA at 240 V is typical for North American 277/480 V panels where the line-to-neutral fault current can be extreme; the 690 V rating of 11.9 kA covers 600 V class Canadian and IEC installations.

Dimensions are 130 mm height, 76.2 mm width, and 70 mm depth — a compact 3-pole footprint that fits standard Siemens 3VA panel cutouts and busbar systems. The TM210 release is thermal-magnetic, adjustable for long-time and instantaneous pickup, with a shunt trip (STL) accessory that accepts a remote trip signal — wired to the auxiliary trip port using the 3VA9688-0BL33 interface.

Frequently asked questions

What is the depth of 3VA1063-4ED32-0KA0?

The depth is 70 mm.

MPN
3VA1063-4ED32-0KA0