Siemens 3VA1063-4ED36-0AA0 SENTRON MCCB, 63 A, 3-Pole, TM210

MPN3VA1063-4ED36-0AA0
Active

Siemens SENTRON 3VA1063-4ED36-0AA0, 3-pole molded case circuit breaker, 63 A rated current, TM210 thermal-magnetic release, 121 kA breaking capacity at 240 V AC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-4ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1063-4ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.3 W
3VA1063-4ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-4ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-4ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1063-4ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-4ED36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1063-4ED36-0AA0 is a 3-pole molded case circuit breaker rated for 63 A continuous current at 40 °C ambient, with no derating needed up to 50 °C. The interrupting capacity hits 121 kA at 240 V AC — enough for high-fault utility feeds — and still delivers 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 500 V and 690 V. That SCCR headroom means it can sit upstream of lower-rated branch devices without cascading failure concerns. Maximum power loss is 17.3 W.

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without surprises. Width of 76.2 mm (3 inches) matches the typical 3-pole cutout for SENTRON 3VA frames. No undervoltage release, no voltage trigger, and no communication function are fitted on this variant — it is a straight thermal-magnetic line-protection device.

Frequently asked questions

Who supplies 3VA1063-4ED36-0AA0 and how is it quoted for volume purchases?

This part is sourced through independent distribution channels and is quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1063-4ED36-0AA0 at different voltages?

Breaking capacity is 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

MPN