Skip to main content
Siemens 3VA1063-4ED36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-4ED36-0BC0 SENTRON MCCB, 63 A, 121 kA at 240

MPN3VA1063-4ED36-0BC0

Siemens SENTRON 3VA1063-4ED36-0BC0, molded case circuit breaker, 3-pole, 63 A rated current at 40 °C, interrupting capacity 121 kA at 240 V, line protection design, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-4ED36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10634ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1063-4ED36-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.8 W
3VA1063-4ED36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-4ED36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-4ED36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1063-4ED36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-4ED36-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1063-4ED36-0BC0 — 63 A MCCB with 121 kA interrupting capacity

The Siemens SENTRON 3VA1063-4ED36-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 63 A at 40 °C and an interrupting capacity of 121 kA at 240 V — that figure drops to 75.6 kA at 415 V and 52.5 kA at 440 V, so verify the available fault current at your service voltage before committing the BOM line. Thermal derating is minimal up to 50 °C (still 63 A), then drops to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C — so for a panel running at 60 °C ambient you lose only 2 A of headroom.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — fits standard panel-mount cutouts for 3-pole MCCBs in the 63 A frame class. The auxiliary switch design accommodates two HQ auxiliary switches, and the breaker ships with the basic switch 3VA10634ED360AA0 — verify the auxiliary contact configuration matches your control circuit wiring before panel integration.

Frequently asked questions

Does 3VA1063-4ED36-0BC0 include an undervoltage release?

Yes, the breaker is designed with an undervoltage release (UVR) as part of the auxiliary release.

MPN
3VA1063-4ED36-0BC0