Skip to main content
Siemens 3VA1063-4ED36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-4ED36-0CH0 SENTRON MCCB, 63 A, 3-Pole, 121 k

MPN3VA1063-4ED36-0CH0

Siemens SENTRON 3VA1063-4ED36-0CH0, molded case circuit breaker, 3-pole, 63 A, line protection, TM210 release, 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1063-4ED36-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1063-4ED36-0CH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1063-4ED36-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1063-4ED36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-4ED36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-4ED36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-4ED36-0CH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB for line protection — 63 A, 3-pole, TM210 release

The Siemens SENTRON 3VA1063-4ED36-0CH0 is a 3-pole molded case circuit breaker rated for a continuous current of 63 A at 40 °C, with the TM210 thermal-magnetic release tuned for line protection. The interrupting capacity reaches 121 kA at 240 V and 75.6 kA at 415 V, giving selectivity headroom for most distribution panels.

Above that, derating is progressive: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C.

The UVR coil is designed for undervoltage protection; the auxiliary contact set provides status feedback for PLC or indication circuits. The auxiliary release order code is 3VA9608-0BB24.

Frequently asked questions

How do I get current pricing and availability for 3VA1063-4ED36-0CH0?

Submit an RFQ through the storefront; the part is sourced to order and pricing is confirmed at quote time.

What is 3VA1063-4ED36-0CH0's listed depth?

The depth is 70 mm.

What is 3VA1063-4ED36-0CH0's listed width?

The width is 76.2 mm.

MPN