Skip to main content
Siemens 3VA1080-2ED32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-2ED32-0HH0 SENTRON MCCB, 80 A, 52.5 kA at 24

MPN3VA1080-2ED32-0HH0

Siemens SENTRON 3VA1080-2ED32-0HH0, molded case circuit breaker, 3-pole, 80 A (40 °C), 52.5 kA at 240 V, line protection, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1080-2ED32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10802ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1080-2ED32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.2 W
3VA1080-2ED32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1080-2ED32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-2ED32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1080-2ED32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-2ED32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It delivers 52.5 kA breaking capacity at 240 V AC, scaling down to 7.5 kA at 690 V — a solid short-circuit rating for most low-voltage switchgear.

The 80 A rating holds flat from 40 °C to 50 °C, then derates gradually to 74 A at 70 °C (–). The 52.5 kA at 240 V is the peak interrupting rating; at 415 V it's 32 kA, still well above typical utility fault levels for a 400 V distribution board. Maximum power loss is 19.2 W — modest for an 80 A frame, so adjacent devices in a DIN-rail row won't see problematic heat buildup.

Integration — what connects where

Dimensions: 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. No undervoltage release — if that's needed, plan an external UVR module.

Frequently asked questions

What is the breaking capacity of 3VA1080-2ED32-0HH0 at 240 V?

52.5 kA at 240 V AC. At 415 V it's 32 kA, at 440 V 13.6 kA, and at 500 V / 690 V it's 7.5 kA (–).

Will 3VA1080-2ED32-0HH0 drop into a panel specified around 3VA1110-5EF32-0AM0 without rewiring?

The 3VA1080-2ED32-0HH0 is a 3-pole 80 A MCCB with a 70 mm depth and 76.2 mm width. The 3VA1110-5EF32-0AM0 is a higher-current variant in the same SENTRON 3VA family — same frame size and mounting pattern, so it will physically fit without panel modifications, but verify the busbar rating and cable sizing for the 80 A load.

Where can I buy 3VA1080-2ED32-0HH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1080-2ED32-0HH0