Siemens 3VA1080-2ED42-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1080-2ED42-0KC0 MCCB, 80 A, 4-Pole, Line

MPN3VA1080-2ED42-0KC0

Siemens SENTRON 3VA1080-2ED42-0KC0, molded case circuit breaker, 80 A rated continuous current, 4 poles, line protection, TM210 overcurrent release, 52.5 kA at 240 V, 32 kA at 415 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1080-2ED42-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1080-2ED42-0KC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C76.8 A
Current at 60 °C75.2 A
Current at 65 °C73.6 A
Current at 70 °C72 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1080-2ED42-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1080-2ED42-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-2ED42-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1080-2ED42-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-2ED42-0KC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Breaking capacity hits 52.5 kA at 240 V and 32 kA at 415 V — enough for most industrial service entrances and feeder circuits.

Above that, it steps down: 76.8 A at 55 °C, 75.2 A at 60 °C, 73.6 A at 65 °C, and 72 A at 70 °C. Plan for it. The 4-pole design switches all phases plus the neutral. There's no N-conductor protection built in — the neutral pole is switched but not monitored for overload. That's standard for line-protection MCCBs in TN-S systems where the neutral is bonded upstream.

Frequently asked questions

Will 3VA1080-2ED42-0KC0 drop into a panel that was specified around 3VA1010-2ED32-0JA0 without rewiring?

Not without checking the mounting and busbar layout. The 3VA1080 is a physically larger frame than the 3VA1010 series — the 3VA1010 is typically narrower and shallower. Panel cutouts, DIN-rail spacing, and busbar connections differ. You'd need to verify dimensions and terminal positions before swapping.