Skip to main content
Siemens 3VA1080-3ED36-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-3ED36-0AE0 SENTRON MCCB, 80A, 75.6kA

MPN3VA1080-3ED36-0AE0

Siemens SENTRON 3VA1080-3ED36-0AE0, molded case circuit breaker, 3-pole, 80 A (40 °C), 75.6 kA at 240 V, TM210 release, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1080-3ED36-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10803ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1080-3ED36-0AE0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.2 W
3VA1080-3ED36-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1080-3ED36-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-3ED36-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts4
3VA1080-3ED36-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-3ED36-0AE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What the TM210 release and auxiliary switch config mean

The TM210 overcurrent release is a fixed thermal-magnetic type. No ground-fault monitoring and no undervoltage release are built in. The design accommodates up to 4 auxiliary switches HQ for status feedback. Power loss is 19.2 W maximum — relevant for thermal budget in a sealed enclosure.

Frequently asked questions

Will 3VA1080-3ED36-0AE0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Yes. Both are 3-pole SENTRON 3VA MCCBs with the same 76.2 mm width and 70 mm depth. The mounting hole pattern and bus-bar pitch are identical — no rewiring needed for a direct swap.

What compliance documentation does this brand provide for 3VA1080-3ED36-0AE0?

As a Siemens SENTRON product, the breaker carries CE marking for the European market and UL/CSA certifications typical for MCCBs. RoHS and REACH declarations are available from Siemens documentation. Verify specific UL file numbers against your local code requirements.

MPN
3VA1080-3ED36-0AE0