Skip to main content
Siemens 3VA1080-3ED42-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-3ED42-0BC0 SENTRON MCCB, 80A, 4-Pole, 75.6kA

MPN3VA1080-3ED42-0BC0

Siemens SENTRON 3VA1080-3ED42-0BC0, molded case circuit breaker (MCCB), line protection, 4-pole, 80 A at 40 °C, 75.6 kA at 240 V, undervoltage release, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1080-3ED42-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10803ED420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1080-3ED42-0BC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.21.7 W
3VA1080-3ED42-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1080-3ED42-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-3ED42-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1080-3ED42-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-3ED42-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Siemens 3VA1080-3ED42-0BC0 — 80 A SENTRON MCCB, line protection, 4-pole

Rated 80 A at 40 °C, it carries a breaking capacity of 75.6 kA at 240 V AC and 52.5 kA at 415 V AC — figures that govern its fault-interruption capability on standard low-voltage mains. Thermal derating is flat from 40 °C to 50 °C (80 A), then drops to 78 A at 55 °C and 74 A at 70 °C (–). For a panel running at 55 °C ambient — common in a crowded enclosure — the breaker delivers 78 A continuous without nuisance tripping. This MCCB includes an undervoltage release and two HQ auxiliary switches. No communication module or ground-fault monitoring is fitted. The trip indicator is absent, so visual status comes from the auxiliary switch contacts wired to a PLC or panel lamp.

Breaking capacity across voltages — what it means for panel design

The 3VA1080-3ED42-0BC0's interrupting rating drops with system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at both 500 V and 690 V (–). On a 415 V distribution board with a prospective short-circuit current of 50 kA, this breaker clears it. At 690 V the same unit only handles 7.5 kA — verify the available fault current before specifying on 690 V supplies.

Dimensions: 130 mm height, 101.6 mm width, 70 mm depth (–). Four-pole form factor occupies the same footprint as a standard SENTRON 4P MCCB; no special cutout needed if the panel already accepts 3VA frame breakers.

Frequently asked questions

Where can I buy 3VA1080-3ED42-0BC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

What is the breaking capacity of 3VA1080-3ED42-0BC0 at 415 V?

The breaking capacity at 415 V is 52.5 kA. At 240 V it is 75.6 kA, and at 440 V it is 32 kA.

MPN
3VA1080-3ED42-0BC0