Siemens 3VA1080-3ED46-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-3ED46-0AF0 SENTRON MCCB, 80 A, 25 kA @ 415 V

MPN3VA1080-3ED46-0AF0

Siemens SENTRON 3VA1 molded case circuit breaker, IEC frame 100, breaking capacity class N, Icu=25 kA @ 415 V, 4-pole, line protection, TM210 release, In=80 A, Ir=80 A fixed, Ii=10 x In, front terminal, 1 auxiliary switch HQ + 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1080-3ED46-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Protection & Trip Unit

3VA1080-3ED46-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1080-3ED46-0AF0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1080-3ED46-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Auxiliary CO contacts2

Environmental

3VA1080-3ED46-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Product details

80 A fixed thermal-magnetic, 25 kA interrupting capacity

The Siemens SENTRON 3VA1080-3ED46-0AF0 is a 4-pole molded case circuit breaker (MCCB) in the 3VA1 frame, rated 80 A continuous with a fixed TM210 thermal-magnetic release. Overload protection Ir is fixed at 80 A; short-circuit pickup Ii is fixed at 10 × In (800 A). The interrupting capacity is 25 kA at 415 V AC (breaking capacity class N per IEC 60947-2), which covers most commercial and light industrial panelboard fault levels without cascading upstream.

Line protection version, 4-pole with unprotected neutral

This is the line protection version — no voltage trip, no undervoltage release, no ground-fault monitoring. The fourth pole switches the neutral conductor but provides no overload or short-circuit protection on that pole (N conductor unprotected). Front-terminal lug connections accept standard panel wiring. The auxiliary contact configuration is one auxiliary switch plus one trip alarm switch, both HQ type; the integrated switch order code is 3VA9988-0AB12.

Environmental and mounting limits

Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Front-face protection is IP40 — suitable for enclosed panel mounting where no water ingress is expected. The 3VA1 frame is designed for DIN-rail or screw-mount integration in standard distribution boards.

Frequently asked questions

What is the trip indicator status on this MCCB?

The trip indicator is present (Yes) — it provides a visual flag when the breaker has tripped on overcurrent or short-circuit.

What is the product version of 3VA1080-3ED46-0AF0?

The product version is line protection — no voltage trip, undervoltage release, or ground-fault monitoring is included.

Where can I buy 3VA1080-3ED46-0AF0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 3VA1080-3ED46-0AF0 drop into a panel specified for 3VA1010-2ED32-0JA0?

Both share the same 3VA1 frame and front-terminal arrangement, but the 3VA1010-2ED32-0JA0 is a 3-pole unit with a shunt trip and 100 A adjustable TM210 release, while this seed is a 4-pole unit with fixed 80 A overload and no shunt trip. Panel cutout and busbar spacing for the 4-pole variant must be verified against the original 3-pole specification.

MPN