Skip to main content
Siemens 3VA1080-4ED42-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-4ED42-0HA0 SENTRON MCCB, 80 A, 4-Pole, 121 k

MPN3VA1080-4ED42-0HA0

Siemens SENTRON 3VA1080-4ED42-0HA0, Molded case circuit breaker, 4-pole, 80 A rated continuous current, TM210 overcurrent release, line protection, 121 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1080-4ED42-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1080-4ED42-0HA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C76.8 A
Current at 60 °C75.2 A
Current at 65 °C73.6 A
Current at 70 °C72 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1080-4ED42-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1080-4ED42-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-4ED42-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1080-4ED42-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-4ED42-0HA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

It is configured for line protection — no ground-fault monitoring, no auxiliary contacts, no communication function. The interrupting ratings are 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V, which means it can clear high-fault currents at common distribution voltages without upstream coordination issues.

The 3VA1080-4ED42-0HA0 measures 130 mm high, 101.6 mm wide, and 70 mm deep. The 4-pole footprint matches standard Siemens 3VA panel cutouts and busbar layouts. It accepts a shunt trip release (order code 3VA9688-0BL30) if remote tripping is needed. No undervoltage release or auxiliary contact module is fitted as shipped — those are add-on accessories. The TM210 release is fixed thermal-magnetic, not electronic, so coordination curves are set at the factory; no field programming required.

Compared to the 3VA1010-2ED32-0JA0, this 3VA1080-4ED42-0HA0 is a higher-current frame (80 A) and carries a 4-pole configuration instead of 3-pole. The 3VA1010-2ED32-0JA0 uses a different release and has a smaller interrupting capacity at equivalent voltages. Panel cutouts differ — the 3VA1080 frame is physically larger, so a direct drop-in without rewiring is not possible.

Frequently asked questions

Does 3VA1080-4ED42-0HA0 include a shunt trip?

It is designed to accept a shunt trip release (order code 3VA9688-0BL30) but does not ship with one fitted. The auxiliary release design is shunt trip (STL).

MPN
3VA1080-4ED42-0HA0