Siemens 3VA1096-3ED32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1096-3ED32-0CA0 SENTRON MCCB, 16A, 3-Pole, 75.6kA

MPN3VA1096-3ED32-0CA0

Siemens SENTRON 3VA1096-3ED32-0CA0, molded case circuit breaker, 3-pole, 16 A rated continuous current, TM210 thermal-magnetic release, breaking capacity 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1096-3ED32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1096-3ED32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C15.36 A
Current at 60 °C15.04 A
Current at 65 °C14.72 A
Current at 70 °C14.4 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA
3VA1096-3ED32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1096-3ED32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1096-3ED32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1096-3ED32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1096-3ED32-0CA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1096-3ED32-0CA0 is a 3-pole molded case circuit breaker (MCCB) rated for 16 A continuous current at 40 °C, with a TM210 thermal-magnetic release — the thermal element handles overloads, the magnetic element handles short-circuits. Breaking capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V, so it clears high-fault events without cascading upstream in most distribution panels. The undervoltage release (UVR) integrated as standard means the breaker trips if control voltage drops, which is typical for emergency-stop or mains-monitoring circuits. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth, so it fits standard SENTRON 3VA panel cutouts and busbar systems.

Above that, it derates linearly: 15.36 A at 55 °C, 15.04 A at 60 °C, 14.72 A at 65 °C, and 14.4 A at 70 °C.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

Breaking capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V.

What type of release does the 3VA1096-3ED32-0CA0 use?

It uses a TM210 thermal-magnetic release — thermal for overload protection, magnetic for short-circuit protection.

Does this breaker include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as standard, which trips the breaker when control voltage drops.

Where can I buy the 3VA1096-3ED32-0CA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN