Skip to main content
Siemens 3VA1110-1AA32-0AD0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1110-1AA32-0AD0 Switch Disconnector, 100 A, 3-Pol

MPN3VA1110-1AA32-0AD0

SENTRON 3VA1110-1AA32-0AD0, IEC frame 160 switch disconnector in MCCB design, 3-pole, rated 100 A continuous, 690 V AC, with 3 HQ auxiliary switches, busbar front terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0AD0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1110-1AA32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W
3VA1110-1AA32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-1AA32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

AC operating voltage is rated 690 V, DC 500 V; insulation voltage is 800 V. It mounts via busbar connection with front terminals, typical for panel feed or load-isolation duty where you need a visible break and lockout capability.

IP40 on the front keeps dust out of the terminal area; the rest of the body is enclosed by the panel. Three built-in HQ auxiliary switches (3 CO contacts) give feedback for status indication or interlocking without needing an add-on block. Mechanical service life is rated 15 000 operating cycles — typical for a disconnect that sees daily switching but not continuous motor starting.

Frequently asked questions

Where can I buy 3VA1110-1AA32-0AD0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the continuous current rating of 3VA1110-1AA32-0AD0?

It is rated 100 A continuous from 40 °C through 70 °C ambient — no derating needed across that range.

Does 3VA1110-1AA32-0AD0 include auxiliary switches?

Yes, it comes with 3 built-in HQ auxiliary switches (3 CO contacts) for status feedback or interlocking.

MPN
3VA1110-1AA32-0AD0