Siemens 3VA1110-1AA32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0AF0 SENTRON Switch Disconnector, 100A

MPN3VA1110-1AA32-0AF0

Siemens SENTRON 3VA1110-1AA32-0AF0, switch disconnector in MCCB design, 3-pole, 100 A rated current (no overload/short-circuit protection), 690 V AC / 500 V DC, 70 mm depth, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0AF0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1110-1AA32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W
3VA1110-1AA32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-1AA32-0AF0 is a SENTRON switch disconnector built in an MCCB-style frame, rated for 100 A continuous current with a flat thermal derating curve — it holds 100 A all the way from 40 °C to 70 °C ambient, so you don't lose headroom as the panel warms up. This is a pure disconnect — no overload protection, no short-circuit protection. It's a load-break switch for isolation and manual switching, not a circuit breaker. The 3-pole version handles three-phase loads up to 690 V AC or 500 V DC. An optional motor drive can be added for remote operation.

That means no derating curve to calculate — if your load pulls 100 A, this switch handles it at 70 °C ambient without a second thought. Max power dissipation is 38 W, so plan for that heat in the enclosure. Mechanical service life is 15,000 operating cycles typical.

The front terminals accept busbar connections, and the nut keeper kit simplifies panel mounting. It's designed for a SENTRON distribution board or a standalone enclosure. The IP40 front protection means it's suited for indoor panel installation where dust ingress is limited. No special sealing gaskets needed for a standard IP40 enclosure.

Frequently asked questions

What is the rated current of 3VA1110-1AA32-0AF0 at elevated temperatures?

It holds 100 A flat from 40 °C to 70 °C — no derating needed across the full operating temperature range.

Does this switch disconnector provide overload or short-circuit protection?

No. It is a pure switch disconnector — no overload protection and no short-circuit protection. It is for isolation and manual switching only.

Where can I buy 3VA1110-1AA32-0AF0 and how is it quoted?

It is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quote.

MPN
3VA1110-1AA32-0AF0