Skip to main content
Siemens 3VA1110-1AA32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0BC0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA32-0BC0

Siemens SENTRON 3VA1110-1AA32-0BC0, IEC frame 160, 3-pole switch disconnector, In=100 A, no overload/short-circuit protection, with undervoltage release (UVR) 24 V DC, 2 auxiliary switches HQ, busbar connection front terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0BC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1110-1AA32-0BC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1110-1AA32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0BC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch disconnector for isolation, not protection

It provides isolation without overload or short-circuit protection. It includes an undervoltage release at 24 V DC and two auxiliary switches.

The 100 A continuous rating (Iu) defines the maximum current the switch can carry without exceeding temperature limits — sized for a feeder or main disconnect on a 100 A branch. The UVR at 24 V DC provides undervoltage protection: if the control voltage drops, the switch trips open. This is a common requirement for motor circuits where loss of control voltage must disconnect the load. The two auxiliary switches (2 CO contacts) give you status feedback for a PLC or indication lamp. The busbar connection and front terminal arrangement mean it's designed for panel mounting with busbar systems — not for DIN-rail clip-on.

Frequently asked questions

What is the depth of 3VA1110-1AA32-0BC0?

The depth is 70 mm, with a width of 76.2 mm and height of 130 mm.

MPN
3VA1110-1AA32-0BC0