Skip to main content
Siemens 3VA1110-1AA32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0CC0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA32-0CC0

Siemens SENTRON 3VA1110-1AA32-0CC0, switch disconnector in MCCB design, 3-pole, 100 A rated continuous current, 690 V AC / 500 V DC, with undervoltage release and 2 auxiliary switches HQ, busbar connection front terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0CC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1110-1AA32-0CC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1110-1AA32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Unlike a standard MCCB, this unit carries no overload or short-circuit protection — it is a straight disconnect-only device, confirmed by the product designation 'switch disconnector' and the absence of any overcurrent release in the spec. What it does include is an undervoltage release (UVR) rated 120-127 V AC 50/60 Hz, plus 2 auxiliary switches HQ (changeover contacts).

Rated continuous current Iu of 100 A sets the maximum uninterrupted load this disconnect can carry. The 3VA1 frame is rated for up to 160 A frame size, so this unit has headroom in the frame but is current-limited by the internal disconnect assembly. Max rated operational voltage is 690 V AC 50/60 Hz and 500 V DC — the AC figure covers standard 400 V and 480 V industrial networks; the DC rating matters for battery banks or DC bus disconnects. The 2 kA limited-time rating (at 1 s and 0.5 s) is the short-time withstand current the disconnect can handle during fault clearing upstream — it is not a breaking capacity, since this is not a circuit breaker. Latching endurance of 15 000 cycles gives a service life baseline for maintenance scheduling.

Where It Goes — Deployment Context

This switch disconnector is designed for panel mounting with front terminals and busbar connection for the main current circuit. The 76.2 mm width (roughly 3 inches) matches standard MCCB panel cutouts — it occupies the same footprint as a 3-pole SENTRON 3VA MCCB.

What It Replaces or Backs Up

If you are replacing a failed switch disconnector in a legacy panel or looking for a critical spare, this 3VA1110-1AA32-0CC0 is a direct fit for any panel originally designed around a 3VA1-frame 3-pole disconnect with UVR and auxiliary contacts. The closest functional peer is the 3VA1110-5EE32-0DC0 — a full molded case circuit breaker with TM220 thermal-magnetic protection, same 100 A rating and same frame. The key difference: the 5EE32 provides overload and short-circuit protection (LI release), while the 1AA32 is disconnect-only. If your application requires overcurrent protection, you need the 5EE32 variant. If you only need a load-break disconnect with undervoltage release, this 1AA32 is the correct choice and avoids paying for protection you won't use.

Frequently asked questions

What is the difference between 3VA1110-1AA32-0CC0 and 3VA1110-5EE32-0DC0?

The 1AA32 is a switch disconnector with no overload or short-circuit protection, while the 5EE32 is a full molded case circuit breaker with a TM220 thermal-magnetic release providing LI protection. Both share the same 100 A rating, 3-pole frame, and dimensions. Choose the 1AA32 for disconnect-only applications; choose the 5EE32 when overcurrent protection is required.

Where can I buy 3VA1110-1AA32-0CC0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the key specifications of 3VA1110-1AA32-0CC0?

Key specs: 3-pole switch disconnector, 100 A rated continuous current (Iu), 690 V AC / 500 V DC max operational voltage, 2 kA short-time withstand (1 s), 15 000 latching endurance cycles, includes undervoltage release (120-127 V AC) and 2 auxiliary switches HQ, IP40 front protection, dimensions 70 x 76.2 x 130 mm.

MPN
3VA1110-1AA32-0CC0