Skip to main content
Siemens 3VA1110-1AA32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0HC0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA32-0HC0

Siemens SENTRON 3VA1 series, switch disconnector in MCCB design, 3-pole, 100 A, shunt trip (STL) 12-30 V DC / 24 V AC, 2 auxiliary switches HQ, IP40 front, busbar connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0HC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1110-1AA32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W
3VA1110-1AA32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1110-1AA32-0HC0 is a 3-pole switch disconnector in MCCB design, rated 100 A flat across the full operating range from 40 °C to 70 °C — no derating curve to chase. The front terminal accepts busbar connection, and the IP40 front face suits enclosed panel mounting where occasional front access is needed.

The 690 V AC / 500 V DC rated operating voltage covers standard 400 V three-phase distribution and many DC bus circuits. Rated insulation voltage at 800 V gives headroom for systems with transient overvoltages up to that level. This is a switch disconnector, not a circuit breaker — there is no overload or short-circuit protection built in. It's intended for isolation and switching under load where the upstream protective device handles fault clearing.

Panel integration

The 76.2 mm width matches the standard 3-pole MCCB footprint for the SENTRON 3VA1 frame 160. Depth of 70 mm and height of 130 mm fit typical DIN-rail or backplate layouts. Front terminals accept busbar connection — plan for busbar routing rather than individual lug terminations. The IP40 front face is fine for enclosed panels; keep it out of direct washdown zones. The shunt trip coil draws power only during the trip event; no continuous hold current. Verify the control voltage matches your system: 12-30 V DC or 24 V AC. The two auxiliary switches are pre-wired with CO contacts — one set for status, one for interlock logic, no extra aux block to buy.

Frequently asked questions

Will 3VA1110-1AA32-0HC0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?

The dimensions match — same 70 mm depth, 76.2 mm width, 130 mm height — so the mechanical fit is identical. The key difference: the 3VA1010-2ED32-0JA0 is a molded case circuit breaker with overcurrent protection, while the 3VA1110-1AA32-0HC0 is a switch disconnector without protection. The wiring interface is different: the breaker uses lug terminals, the disconnector uses busbar connection. You cannot simply swap one for the other without reviewing the circuit protection scheme and busbar layout.

Where can I buy 3VA1110-1AA32-0HC0?

This part is sourced to order through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
3VA1110-1AA32-0HC0