Siemens 3VA1110-1AA32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0JC0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA32-0JC0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector SD100, 3-pole, In=100 A, without overload or short-circuit protection, shunt trip (STL) 110-127 V DC/AC 50/60 Hz, 2 auxiliary switches HQ, IP40 front, busbar connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0JC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1110-1AA32-0JC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1110-1AA32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0JC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-1AA32-0JC0 is a SENTRON 3VA1 switch disconnector in the IEC frame 160 footprint — 70 mm deep, 76.2 mm wide, 130 mm tall — rated for 100 A continuous current (Iu) with a maximum AC operational voltage of 690 V and DC operational voltage of 500 V.

Where this part fits in a panel

This is a 3-pole disconnect with busbar connection on the main circuit and front terminals. The 76.2 mm width matches the 3VA1 frame-160 footprint, so it slots into a multi-unit distribution block alongside MCCBs or other disconnectors on the same busbar system. Maximum power loss is 38 W. Verify the enclosure thermal budget if densely packed.

The 100 A rated continuous current (Iu) at 690 V AC means this disconnect can carry 100 A indefinitely without overheating — sized for a 100 A feeder or branch circuit. The 2 kA limited short-time withstand (1 s and 0.5 s) tells you this disconnect can survive a fault current of 2 kA for up to one second — enough for coordination with upstream protective devices that clear faster. It is not a circuit breaker, so it relies on an upstream breaker or fuse to interrupt fault current; the disconnect just needs to hold together until the upstream device opens.

Frequently asked questions

Will 3VA1110-1AA32-0JC0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?

Both parts share the same 70 mm depth, 76.2 mm width, and 130 mm height, and both use front terminals for the main circuit. However, the 3VA1110-1AA32-0JC0 uses busbar connection while the 3VA1110-5EE32-0JA0 uses lug terminal connection, so the busbar arrangement may differ. The mechanical footprint is identical, but verify the busbar kit compatibility before assuming a direct swap.

MPN
3VA1110-1AA32-0JC0