Skip to main content
Siemens 3VA1110-1AA32-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA32-0KC0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA32-0KC0

Siemens SENTRON 3VA1110-1AA32-0KC0, switch disconnector in MCCB design, IEC frame 160, 3-pole, In = 100 A, without overload or short-circuit protection, shunt trip (STL) 220-250 V DC / 208-277 V AC, 2 auxiliary switches HQ, front busbar connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA32-0KC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1110-1AA32-0KC0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1110-1AA32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA32-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA32-0KC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-1AA32-0KC0 is a SENTRON switch disconnector built in a 3-pole MCCB-style housing on the IEC frame 160 platform. Rated continuous current Iu is 100 A, with a rated insulation voltage Ui of 800 V and max operating voltage of 690 V AC at 50/60 Hz or 500 V DC. This is a pure disconnect — no overload or short-circuit protection elements inside. It's designed for manual isolation and switching of loads where the upstream protection is handled by a separate device. The integrated shunt trip (STL) release operates on 220-250 V DC or 208-277 V AC, letting you remotely trip the disconnect via a control signal. The unit also carries a voltage trigger for undervoltage or remote trip monitoring.

Panel footprint is 76.2 mm wide by 130 mm tall by 70 mm deep — the standard 3-pole MCCB cutout for the SENTRON 3VA frame 160 family. Main circuit connection is via front busbar terminals; the busbar connection type means it's meant for horizontal or vertical busbar systems in a distribution panel, not lugged cable entry. Auxiliary contacts and the shunt trip are factory-fitted — no field-kit installation needed. The unit accepts an optional motor drive for remote motorized operation if the application requires it.

The 100 A continuous rating is the current it can carry indefinitely without exceeding temperature limits — sized for a 100 A feeder or load circuit. The 800 V insulation voltage means it's suitable for 400/480 V and 690 V systems with adequate clearance. The 2 kA short-time withstand at 1 s and 0.5 s is the fault current it can hold closed during coordination; it's not a breaking capacity rating since this is a disconnect, not a circuit breaker. The shunt trip coil draws its power from the control voltage — verify the control transformer or DC supply can source the inrush. The 2 HQ auxiliary switches are rated for typical control circuit loads; they share the same terminal compartment as the main busbar connection.

Frequently asked questions

Where can I buy 3VA1110-1AA32-0KC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA1110-1AA32-0KC0 drop into a panel specified around 3VA1110-5EE32-0JA0?

Yes — both share the same 76.2 mm width, 130 mm height, 70 mm depth, and front-terminal busbar connection on the SENTRON 3VA frame 160 platform. The difference is function: the -1AA32 is a switch disconnector without overcurrent protection, while the -5EE32 is a molded case circuit breaker with a TM220 thermal-magnetic release. Panel cutout and busbar layout are identical.

What are the key ratings of this switch disconnector?

Rated continuous current Iu is 100 A. Rated insulation voltage Ui is 800 V. Max operating voltage is 690 V AC at 50/60 Hz or 500 V DC. Short-time withstand is 2 kA at 1 s and 0.5 s. Power loss is 38 W maximum.

MPN
3VA1110-1AA32-0KC0