Siemens 3VA1110-1AA36-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA36-0AH0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA36-0AH0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector, 3-pole SD100, In=100 A, without overload or short-circuit protection, clamp connection, 2 auxiliary switches HQ + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA36-0AH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1110-1AA36-0AH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1110-1AA36-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA36-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-1AA36-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA36-0AH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Switch disconnector, 100 A, 3-pole — SENTRON 3VA1 frame 160

The Siemens 3VA1110-1AA36-0AH0 is a SENTRON 3VA1 IEC frame 160 switch disconnector rated at 100 A continuous current (Iu) with 3 poles, designed for isolation and switching without built-in overload or short-circuit protection — it's a pure disconnect, not a molded case circuit breaker (MCCB). Rated insulation voltage is 800 V (Ui), with max operational voltage 690 V AC 50/60 Hz and 500 V DC, so it handles standard 400 V three-phase panels and 480 V industrial supplies comfortably.

The 100 A continuous rating (Iu) at 70 °C max ambient means this disconnect can carry full load current in a warm enclosure without derating below 100 A. IP40 on the front means the operator face is protected against solid objects over 1 mm (tools, wires) but not against water — install inside a panel with a higher-rated door or gland plate for wet environments. Mechanical endurance of 15,000 operating cycles (latching endurance) suits frequent manual switching in a production line isolation point.

No official successor order code exists — this is the active variant for the 100 A switch disconnector role in the 3VA1 frame 160 family.

Footprint: 130 mm height, 76.2 mm width (3-inch wide), 70 mm depth — fits standard 3-pole MCCB cutouts on a DIN rail or panel-mount adapter plate. Front terminal arrangement for main circuit conductors; auxiliary contacts are pre-wired with screw terminals — strip length and torque per Siemens installation manual (not reproduced here). Optional motor drive can be added (product extension optional) for remote switching — verify the drive catalog number separately.

Frequently asked questions

Will 3VA1110-1AA36-0AH0 drop into a panel specified for 3VA1110-5ED36-0AC0 without rewiring?

Yes — both share the same 130 x 76.2 x 70 mm footprint, 3-pole front terminal arrangement, and SENTRON 3VA1 frame 160 platform, so mechanical fit is identical. The difference is functional: the -5ED36-0AC0 is a molded case circuit breaker with overcurrent release (TM210), while the -1AA36-0AH0 is a pure switch disconnector with no overload or short-circuit protection. If the panel design relies on the breaker's trip function, a straight swap is not electrically equivalent — you would need to add separate overcurrent protection upstream or downstream.

MPN
3VA1110-1AA36-0AH0