Skip to main content
Siemens 3VA1110-1AA36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA36-0CA0 SENTRON Switch Disconnector, 100

MPN3VA1110-1AA36-0CA0

Siemens SENTRON 3VA1110-1AA36-0CA0, switch disconnector in MCCB design, 3-pole, In=100 A, without overload or short-circuit protection, front terminal connection, undervoltage release 120-127 V AC 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA36-0CA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1110-1AA36-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W
3VA1110-1AA36-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA36-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-1AA36-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA36-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-1AA36-0CA0 is a SENTRON switch disconnector in a molded-case circuit breaker (MCCB) design — 3-pole, rated 100 A, with no overload or short-circuit protection built in. It's a pure disconnect, sized for the 3VA1 frame (160 A frame), and it carries an undervoltage release (UVR) coil rated 120-127 V AC 50/60 Hz. Rated insulation voltage is 800 V, operating voltage 690 V AC or 500 V DC, so it handles standard 400/480 V panels and some DC bus work. Termination is front-terminal clamp connection, which means you can land cables without pulling the unit off the DIN rail. Mechanical life is rated 15,000 operating cycles — typical for a panel disconnect that sees daily use but not continuous switching.

What the undervoltage release means on site

The UVR (undervoltage release) on this 3VA1110-1AA36-0CA0 is a factory-fitted auxiliary release that trips the disconnect when the control voltage drops below about 70% of its 120-127 V AC rating. That's a standard safety feature for conveyors, pumps, or any load that must not auto-restart after a power dip — the UVR holds the contacts open until the control circuit is deliberately re-energized. It does NOT have a leading contact (= No), so the UVR doesn't sequence ahead of the main contacts. If you need that for delayed dropout on a motor circuit, you'd spec a different variant or add an external time-delay relay. The UVR coil is 120-127 V AC only — don't feed it 240 V control power without a step-down transformer.

That said, the 3VA1 frame is a mature platform. If you're filling a BOM line or replacing a failed unit in a live panel, this order code is the direct drop-in.

Panel fit and physical constraints

Dimensions are 70 mm deep, 76.2 mm wide, 130 mm tall — standard 3-pole MCCB footprint for the 160 A frame. It mounts on DIN rail (implied by the MCCB design) and the front-terminal connection keeps wiring accessible without removing adjacent units.

Frequently asked questions

What is the 3VA1110-1AA36-0CA0 rated for in terms of current and voltage?

Rated 100 A continuous at ambient temperatures from 40 °C to 70 °C with no derating. Operating voltage is 690 V AC or 500 V DC; insulation voltage is 800 V.

Does the 3VA1110-1AA36-0CA0 provide overload or short-circuit protection?

No. This is a switch disconnector only — it has no overload release and no short-circuit protection. It's a manual disconnect with an undervoltage release for safety isolation.

What is the closest functional second-source to the 3VA1110-1AA36-0CA0?

The 3VA1110-5ED36-0AC0 is a close sibling — same frame, same 100 A rating, same physical footprint (70 mm deep, 76.2 mm wide, 130 mm tall). The key difference: the -5ED36 variant is a full molded-case circuit breaker with thermal-magnetic overcurrent protection (TM210 release) and 2 auxiliary switches, while the -1AA36 is a bare switch disconnector with only the UVR. They share the same mounting hole pattern and terminal arrangement, so a panel wired for one can usually accept the other with no rework, but the circuit protection function and wiring of the auxiliary contacts differ.

Where can I buy the 3VA1110-1AA36-0CA0 and get current pricing?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote on this order code.

MPN
3VA1110-1AA36-0CA0