Skip to main content
Siemens 3VA1110-1AA36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA36-0CC0 SENTRON Switch Disconnector, 100A

MPN3VA1110-1AA36-0CC0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole, 100 A, 690 V AC, front terminal connection, undervoltage release 120-127 V AC 50/60 Hz, 2 HQ auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1110-1AA36-0CC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON

Ratings

3VA1110-1AA36-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W

Construction & Connection

3VA1110-1AA36-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1110-1AA36-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1110-1AA36-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1110-1AA36-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What It Is and What It Does

The Siemens 3VA1110-1AA36-0CC0 is a SENTRON 3VA1 switch disconnector in an MCCB-style housing, rated for 100 A continuous at 40 °C through 70 °C without derating — a flat thermal curve that simplifies panel sizing in warm environments. It is a 3-pole device with a rated insulation voltage of 800 V and an operating voltage of 690 V AC or 500 V DC, making it suitable for isolating motor feeders, distribution sub-circuits, or transformer primaries in industrial switchgear.

Key Ratings and What They Mean for Fit

The 100 A rating holds across the full ambient range of 40 °C to 70 °C — no thermal derating curve to calculate. That simplifies BOM validation: if your load is 100 A or less, this switch disconnector fits without temperature-related headroom. The 690 V AC operating voltage covers standard 400 V and 480 V systems with margin for line-to-line transients. The 800 V insulation voltage confirms it is rated for use in 690 V networks per IEC 60947. The unit includes an undervoltage release (UVR) rated 120-127 V AC 50/60 Hz, plus two HQ auxiliary switches (form C, 2 CO contacts). The UVR trips the switch when control voltage drops below the dropout threshold — a standard safety interlock for motor starters or emergency-off circuits. The auxiliary switches provide status feedback to a PLC or indicator lamp without an add-on block.

Panel Integration and Mounting

The switch disconnector measures 70 mm deep, 76.2 mm wide, and 130 mm high — a 3-pole MCCB footprint that fits standard DIN-rail or panel-mount enclosures. Front terminal connections for the main circuit simplify wiring access in a crowded cabinet. IP40 on the front means protection against tools and wires >1 mm; the unit is intended for indoor switchgear, not washdown environments.

Frequently asked questions

Will 3VA1110-1AA36-0CC0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Yes — both share the same 70 mm depth, 76.2 mm width, and 130 mm height, and both use front terminal connections for the main circuit. The mounting footprint and terminal arrangement are identical, so no panel modification or rewiring is needed for the swap.

MPN
3VA1110-1AA36-0CC0