Siemens 3VA1110-1AA36-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-1AA36-0CC0 SENTRON Switch Disconnector, 100A

MPN3VA1110-1AA36-0CC0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 3-pole, 100 A, 690 V AC, front terminal connection, undervoltage release 120-127 V AC 50/60 Hz, 2 HQ auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-1AA36-0CC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1110-1AA36-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C100 A
Current at 60 °C100 A
Current at 65 °C100 A
Current at 70 °C100 A
Power loss, max.38 W
3VA1110-1AA36-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-1AA36-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-1AA36-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-1AA36-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-1AA36-0CC0 is a SENTRON 3VA1 switch disconnector in an MCCB-style housing, rated for 100 A continuous at 40 °C through 70 °C without derating — a flat thermal curve that simplifies panel sizing in warm environments.

That simplifies BOM validation: if your load is 100 A or less, this switch disconnector fits without temperature-related headroom. The 800 V insulation voltage confirms it is rated for use in 690 V networks per IEC 60947.

The switch disconnector measures 70 mm deep, 76.2 mm wide, and 130 mm high — a 3-pole MCCB footprint that fits standard DIN-rail or panel-mount enclosures. Front terminal connections for the main circuit simplify wiring access in a crowded cabinet.

Frequently asked questions

Will 3VA1110-1AA36-0CC0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Yes — both share the same 70 mm depth, 76.2 mm width, and 130 mm height, and both use front terminal connections for the main circuit. The mounting footprint and terminal arrangement are identical, so no panel modification or rewiring is needed for the swap.