Siemens 3VA1110-3ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-3ED12-0AA0 SENTRON MCCB, 1-Pole, 100 A, 52.5

MPN3VA1110-3ED12-0AA0
Active

Siemens SENTRON 3VA1110-3ED12-0AA0, 1-pole molded case circuit breaker, 100 A, TM210 overcurrent release, line protection, interrupting rating 52.5 kA at 240 V AC, 7.5 kA at 415 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1110-3ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1110-3ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V7.5 kA
Power loss, max.8.33 W

Protection & Trip Unit

3VA1110-3ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1110-3ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1110-3ED12-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1110-3ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1110-3ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1110-3ED12-0AA0 is a 1-pole molded case circuit breaker rated 100 A at 40 °C, built for line-protection duty with a TM210 thermal-magnetic overcurrent release. It carries a 52.5 kA interrupting rating at 240 V AC and 7.5 kA at 415 V AC — enough to handle high-fault utility feeds in a distribution panel. The 25.4 mm width (1 in) lets it fit a standard single-pole MCCB slot without extra panel space.

Ratings and derating

Rated 100 A continuous at 40 °C ambient; holds that rating up to 50 °C. Above that it steps down: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. If the panel runs warm — near a transformer or tightly packed breakers — the 70 °C derating to 91 A is the number to use for your load budget.

Mounting and integration

Mounts on a DIN rail or panel-mount base. The 70 mm depth and 130 mm height fit standard 1-pole MCCB cutouts. Front IP40 protects against tool contact in a closed panel; no additional gland plate sealing is needed for typical indoor distribution boards.

Frequently asked questions

Where can I buy 3VA1110-3ED12-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the interrupting rating of 3VA1110-3ED12-0AA0?

It interrupts 52.5 kA at 240 V AC and 7.5 kA at 415 V AC — suitable for high-fault-capacity service entrance or feeder panels.

What is the width of 3VA1110-3ED12-0AA0?

The width is 25.4 mm (1 in), a standard single-pole MCCB footprint.

What compliance documentation does this brand provide?

The SENTRON series typically ships with RoHS and REACH declarations; UL and IEC certifications are standard for the 3VA platform. Specific documentation is included with the unit or available on request.

MPN
3VA1110-3ED12-0AA0