Skip to main content
Siemens 3VA1110-3ED16-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-3ED16-0AA0 SENTRON MCCB, 100 A, 1-Pole

MPN3VA1110-3ED16-0AA0
Active

Siemens SENTRON 3VA1110-3ED16-0AA0, molded case circuit breaker, 1-pole, 100 A rated current at 40 °C, TM210 release, breaking capacity 52.5 kA at 240 V AC.

$199.18 – $207.48Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1110-3ED16-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-3ED16-0AA0 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V7.5 kA
Power loss, max.8.33 W
3VA1110-3ED16-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-3ED16-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-3ED16-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1110-3ED16-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-3ED16-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

100 A, 1-pole MCCB with TM210 release

The 3VA1110-3ED16-0AA0: The TM210 thermal-magnetic release gives you fixed overload protection and short-circuit response; there is no separate undervoltage or shunt trip module on this variant.

At 240 V, the 52.5 kA Icu gives solid headroom for high-fault service entrances; at 415 V the 7.5 kA still covers most distribution boards but verify against your transformer impedance and cable run.

Rated insulation voltage is 500 V, operating voltage 415 V AC or 125 V DC, with a maximum power loss of 8.33 W at rated load.

Frequently asked questions

What is the overload protection setting (Ir) and short-circuit protection (Ii) for 3VA1110-3ED16-0AA0?

The breaker uses a TM210 thermal-magnetic release. The thermal element provides fixed overload protection at 100 A (no adjustable Ir); the magnetic short-circuit pickup is factory-set per the TM210 curve. The datasheet gives the exact Ii threshold.

MPN
3VA1110-3ED16-0AA0