Skip to main content
Siemens 3VA1110-3ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-3ED46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 75.6

MPN3VA1110-3ED46-0AA0
Active

Siemens SENTRON 3VA1110-3ED46-0AA0, molded case circuit breaker, 4-pole, 100 A at 40 °C, TM210 thermal-magnetic release, 75.6 kA interrupting at 240 V, IP40 front.

$143.51Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-3ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-3ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W
3VA1110-3ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-3ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-3ED46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-3ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-3ED46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

SENTRON 3VA1110-3ED46-0AA0 — MCCB for Line Protection

The Siemens 3VA1110-3ED46-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection, carrying a continuous current rating of 100 A at 40 °C with no derating needed up to 50 °C — above that it drops to 98 A at 55 °C and 91 A at 70 °C, so if your panel ambient runs hot, that's the number to size against. Interrupting capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and 11.9 kA at 690 V, which covers most industrial service-entrance and distribution panel fault duties.

If you're freezing a BOM or managing a long-term project, the SENTRON 3VA platform is Siemens' main MCCB family, so replacement parts and accessories (auxiliary contacts, shunt trips, rotary handles) are standard catalog items. No second-source cross-reference needed — this is the primary line.

Physical Fit & Panel Integration

Dimensions: 130 mm tall, 101.6 mm wide, 70 mm deep — a 4-pole MCCB footprint that fits standard Siemens SENTRON mounting plates and panel cutouts.

Frequently asked questions

What is the interrupting capacity of 3VA1110-3ED46-0AA0 at 240 V?

75.6 kA at 240 V. It also delivers 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V.

What does the TM210 release designation mean?

TM210 means a thermal-magnetic release with a fixed 100 A thermal element and an adjustable magnetic trip — the '210' code indicates the 100 A rating level in Siemens' naming convention.

Where can I buy 3VA1110-3ED46-0AA0 and get current pricing?

We source this part to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What compliance documentation does this MCCB carry?

As a Siemens SENTRON product, it is designed to meet IEC 60947-2 and UL 489 standards for molded case circuit breakers. Specific RoHS, REACH, and CE declarations are available from Siemens' documentation portal using the order code.

MPN
3VA1110-3ED46-0AA0