Siemens SENTRON 3VA1110-3EE32-0AA0, molded case circuit breaker, 3-pole, 100 A at 40 °C, TM220 overcurrent release, 75.6 kA interrupting at 240 V, IP40 front, current lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-3EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-3EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W
3VA1110-3EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-3EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-3EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-3EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-3EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

3VA1110-3EE32-0AA0 — SENTRON MCCB, 100 A, TM220 Release

The Siemens SENTRON 3VA1110-3EE32-0AA0 is a 3-pole molded case circuit breaker rated 100 A at 40 °C, with a TM220 thermal-magnetic overcurrent release designed for line protection. Its interrupting capacity hits 75.6 kA at 240 V and still delivers 52.5 kA at 415 V — enough headroom for most industrial distribution panels without cascading upstream.

Ratings That Drive the Fit

The 100 A rating holds flat from 40 °C through 50 °C, then derates gradually to 91 A at 70 °C — a useful curve for warm enclosures where you don't want to oversize the frame just for ambient. Interrupting capacity drops with voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V. Selectivity studies should use the voltage closest to your system's bolted-fault level. The TM220 release means a fixed thermal pickup and magnetic trip — no interchangeable trip units, but also no adjustment errors in the field. Designed for straightforward line protection, not motor or generator circuits.

Panel Integration