Skip to main content
Siemens 3VA1110-3EF32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-3EF32-0JC0 SENTRON MCCB, 100A, 3-Pole, 75.6k

MPN3VA1110-3EF32-0JC0

Siemens SENTRON 3VA1110-3EF32-0JC0, molded case circuit breaker, 3-pole, 100 A rated at 40 °C, 70 mm depth, line protection design with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1110-3EF32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11103EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1110-3EF32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W

Protection & Trip Unit

3VA1110-3EF32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1110-3EF32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1110-3EF32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1110-3EF32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1110-3EF32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB carries and where it fits

The Siemens 3VA1110-3EF32-0JC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated 100 A continuously at 40 °C ambient, with a line-protection trip curve. It carries a 75.6 kA interrupting capacity at 240 V AC, stepping down to 52.5 kA at 415 V and 32 kA at 440 V — still enough headroom for most 400 V distribution panels. The 800 V rated insulation voltage means it is comfortable in 480 V or 600 V industrial services as well. The breaker is fitted with a shunt trip (STL) for remote opening and two HQ auxiliary switches for status feedback to a PLC or annunciator. No undervoltage release, no ground-fault module, no communication function — this is a straightforward line-protection device for a main or feeder breaker position. The 25 W maximum power loss is manageable in a standard enclosure, but factor it into the thermal budget if the panel is tightly packed.

Thermal derating and real-world current

The 100 A rating holds from 40 °C up to 50 °C ambient. Above that, derate linearly: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. If the panel sits in a hot mechanical room or near a furnace, the 70 °C figure is the one to design against. The operating temperature range is -25 °C to +70 °C, storage from -40 °C to +80 °C — fine for unconditioned warehouses or outdoor enclosures in temperate climates.

Panel fit and mounting

The breaker footprint is 76.2 mm wide (3 in), 130 mm tall (5.12 in), and 70 mm deep (2.76 in) — standard 3-pole MCCB form factor for DIN-rail or backplate mounting. The 70 mm depth leaves room behind a 200 mm deep enclosure for wiring and the shunt trip leads. Verify gland-plate clearance if using a shallow 150 mm box.

Frequently asked questions

What are the key ratings for 3VA1110-3EF32-0JC0?

Rated 100 A continuous at 40 °C, 3-pole, with a breaking capacity of 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V. Insulation voltage is 800 V. Includes a shunt trip and two auxiliary switches.

What is the depth of this MCCB?

The depth is 70 mm (2.76 in).

What is the width of this MCCB?

The width is 76.2 mm (3 in).

Where can I buy 3VA1110-3EF32-0JC0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm quote.

Will 3VA1110-3EF32-0JC0 drop into a panel specified for 3VA1110-5ED36-0AC0?

Both are 3-pole SENTRON MCCBs with the same 76.2 mm width and 130 mm height, so the physical footprint is identical. The difference is in the trip unit and accessories — verify the shunt trip wiring and auxiliary contact configuration against your panel schematic before swapping.

MPN
3VA1110-3EF32-0JC0