Skip to main content
Siemens 3VA1110-3EF36-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-3EF36-0JC0 SENTRON MCCB, 100 A, 3-Pole, 75.6

MPN3VA1110-3EF36-0JC0

Siemens SENTRON 3VA1110-3EF36-0JC0, molded case circuit breaker, 3-pole, 100 A at 40 °C, 75.6 kA at 240 V, line protection design, with shunt trip (STL) and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-3EF36-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11103EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1110-3EF36-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W
3VA1110-3EF36-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-3EF36-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-3EF36-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-3EF36-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-3EF36-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Its headline rating is 100 A at 40 °C, meaning it carries that load continuously without tripping at typical panel ambient — and it holds that same 100 A rating through 50 °C, so no derating is needed for most indoor switchgear rooms; only above 55 °C does it start to step down, reaching 91 A at 70 °C. The interrupting capacity is 75.6 kA at 240 V, dropping to 52.5 kA at 415 V and 32 kA at 440 V — sufficient for high-fault industrial services where fault current can exceed 50 kA.

There is no announced phase-out or last-time-buy window. For a BOM freeze or MRO spare, this part is a standard catalog line, not a sunset item that requires obsolescence planning.

Panel integration — what fits where

The MCCB measures 70 mm deep, 76.2 mm wide, and 130 mm tall — a standard 3-pole MCCB footprint that drops into most SENTRON distribution panels and switchgear cubicles without re-drilling. Maximum power loss is 25 W — account for this in thermal calculations for enclosed panels, especially when multiple breakers are ganged.

The closest functional peer is the 3VA1110-5ED36-0AC0. Both are 3-pole SENTRON MCCBs with the same frame size and 100 A thermal rating. The -3EF36-0JC0 includes a shunt trip and two HQ aux switches as standard.

Frequently asked questions

Will 3VA1110-3EF36-0JC0 drop into a panel designed for 3VA1110-5ED36-0AC0?

Yes — both share the same 70 mm depth, 76.2 mm width, and 130 mm height, so no panel modification or rewiring is needed.

MPN
3VA1110-3EF36-0JC0