Skip to main content
Siemens 3VA1110-4ED22-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-4ED22-0AA0 SENTRON MCCB, 100 A, 2-Pole, 121

MPN3VA1110-4ED22-0AA0
Active

Siemens SENTRON 3VA1110-4ED22-0AA0, Molded case circuit breaker, 2-pole, 100 A continuous, 121 kA breaking capacity at 240 V AC, TM210 release, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-4ED22-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-4ED22-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Power loss, max.16.66 W
3VA1110-4ED22-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-4ED22-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-4ED22-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1110-4ED22-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-4ED22-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The Siemens 3VA1110-4ED22-0AA0 is a SENTRON molded case circuit breaker (MCCB) for line protection, rated 100 A continuous at 40 °C ambient and carrying a 121 kA interrupting capacity at 240 V AC — that means it can safely clear a fault up to 121 kA without welding contacts or rupturing, which is the figure that governs your SCCR coordination downstream.

Ratings that drive the panel design

The 100 A rating holds across 40 °C, 45 °C, and 50 °C (–), then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C (–). Dimensions: 70 mm deep, 50.8 mm wide, 130 mm high (–). Fits standard DIN-rail or panel-mount footprints for a 2-pole MCCB.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

121 kA at 240 V AC. At 415 V AC it is 75.6 kA. Use the lower figure for your SCCR coordination if the line-to-line voltage exceeds 240 V.

Where can I buy 3VA1110-4ED22-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Send a request with your quantity and target delivery window; availability and current pricing are confirmed at quote time.

MPN
3VA1110-4ED22-0AA0