Skip to main content
Siemens 3VA1110-4EF32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-4EF32-0AA0-ZD00 Circuit Breaker, 36kA @ 415V

MPN3VA1110-4EF32-0AA0-ZD00

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class S, Icu=36kA @ 415V, 3-pole, line protection TM240, ATAM, In=100A overload protection Ir=70A...100A, short-circuit protection Ii=5...10 x In, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1110-4EF32-0AA0-ZD00 is an IEC frame 160 molded-case circuit breaker (MCCB) in the 3VA1 series, rated for 36 kA interrupting capacity at 415 V AC across three poles. The TM240 thermal-magnetic trip unit provides adjustable overload protection from 70 A to 100 A (Ir) and fixed short-circuit protection set at 5 to 10 times In (Ii). This variant includes a nut keeper kit, configured for a DC Power OEM application in China.

For a 415 V distribution board feeding motor control centers or transformer secondaries, this rating handles the prospective short-circuit current typical of a 1 MVA to 2 MVA transformer secondary. The 100 A frame and adjustable Ir (70–100 A) let you size the overload to the actual load, not the frame max, avoiding nuisance trips on a 75 A conveyor drive or 80 A pump feeder.

Deployment context

The nut keeper kit indicates the breaker ships with captive hardware for the DC Power OEM's busbar or cable lug connections — a detail that saves panel-build time compared to sourcing loose hardware.

Frequently asked questions

Where can I buy 3VA1110-4EF32-0AA0-ZD00 and get a price?

This part is sourced and quoted to order through independent distribution. Submit an RFQ to confirm current availability and pricing for your required quantity.

What does the 36 kA breaking capacity at 415 V mean for my panel?

The 36 kA Icu rating means this breaker can safely interrupt a fault current up to 36,000 amps at 415 V AC without failing — sufficient for most industrial distribution boards fed by transformers up to about 2 MVA.

What is the adjustable overload range on this breaker?

The TM240 thermal-magnetic trip unit allows overload protection adjustment from 70 A to 100 A (Ir), with short-circuit pickup (Ii) fixed at 5 to 10 times the rated current In of 100 A.

MPN