Skip to main content
Siemens 3VA1110-4EF36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-4EF36-0AA0 SENTRON MCCB, 100 A, 3-Pole, 121

MPN3VA1110-4EF36-0AA0
Active

Siemens SENTRON 3VA1110-4EF36-0AA0, 3-pole molded case circuit breaker, 100 A at 40 °C, TM240 release, 121 kA at 240 V, line protection.

$135.89Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-4EF36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-4EF36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.25 W
3VA1110-4EF36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-4EF36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-4EF36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-4EF36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-4EF36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 100 A continuous, 121 kA interrupting

The Siemens SENTRON 3VA1110-4EF36-0AA0 is a 3-pole molded case circuit breaker rated for 100 A continuous at 40 °C, with a TM240 thermal-magnetic release designed for line protection. Its interrupting capacity reaches 121 kA at 240 V AC and 75.6 kA at 415 V AC, giving the panel builder headroom for high-fault installations where upstream coordination demands a robust first-level breaker. For a BOM line, confirm the 100 A matches your load side; the frame itself can be re-rated up to 240 A with the correct plug if the panel is later upsized.

Lifecycle and compliance — active, current-production part

For compliance documentation, the SENTRON 3VA series carries UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications as standard. RoHS and REACH declarations are available from Siemens per the product family. If your customer's AML requires a specific cert (e.g., UL file number), the nameplate marking on the unit will list the applicable standards — the part ships with the standard compliance marking for North American and European markets.

No communication function, undervoltage release, or ground-fault monitoring is built into this variant — those are separate accessory modules that mount externally.

Frequently asked questions

Will 3VA1110-4EF36-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0?

Yes, both share the same 70x76.2x130 mm footprint and 3-pole configuration, so no rewiring or busbar changes are needed for the swap.

MPN
3VA1110-4EF36-0AA0