Siemens 3VA1110-5ED32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5ED32-0AH0 SENTRON MCCB, 100A, 3-Pole, 187kA

MPN3VA1110-5ED32-0AH0

Siemens SENTRON 3VA1110-5ED32-0AH0, 3-pole molded case circuit breaker, 100 A at 40 °C, TM210 thermal-magnetic release, 187 kA interrupting at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5ED32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11105ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1110-5ED32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-5ED32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-5ED32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5ED32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-5ED32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5ED32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1110-5ED32-0AH0 is a Siemens SENTRON 3-pole MCCB rated for line-protection duty — meaning it sits at the feeder or main branch in a distribution panel, not on a motor or a specific load. Its continuous current holds 100 A from 40 °C through 50 °C without derating, then drops to 98 A at 55 °C and 91 A at 70 °C (the operating maximum). That thermal curve matters: if your panel ambient runs at 55 °C, you lose 2 A off the nameplate; at 65 °C you lose 6 A. The TM210 thermal-magnetic release gives a fixed thermal pickup plus magnetic trip for short-circuit events — no electronic adjustment, so it's a set-and-forget part for standard distribution. At 240 V it clears 187 kA — that's the highest single rating on the ledger and covers most industrial services. At 415 V it still handles 121 kA, at 440 V it's 75.6 kA, and at 500 V or 690 V it drops to 17 kA. If your fault current at 480 V is above 17 kA, this breaker is not the right pick — you need a higher-rated frame.

MPN
3VA1110-5ED32-0AH0