Siemens 3VA1110-5ED32-0BC0 SENTRON MCCB, 100 A, 3-Pole, TM21

MPN3VA1110-5ED32-0BC0

Siemens SENTRON 3VA1110-5ED32-0BC0, molded case circuit breaker (MCCB), 3-pole, 100 A, TM210 thermal-magnetic release, line protection, 187 kA at 240 V, undervoltage release included, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5ED32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1110-5ED32-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1110-5ED32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1110-5ED32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5ED32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-5ED32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5ED32-0BC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1110-5ED32-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated for a continuous current of 100 A at 40 °C, with a TM210 thermal-magnetic release for line protection. It carries an impressive 187 kA interrupting capacity at 240 V, tapering to 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — this is the SCCR you need for high-fault panels where upstream coordination matters.

Current derating and ambient limits

Above that it derates linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C.

The 3-pole footprint matches the standard SENTRON 3VA1110 frame; if you are swapping from a different brand, check the busbar pitch and terminal centerline against your existing panel layout.

Frequently asked questions

What are the key ratings for 3VA1110-5ED32-0BC0?

Rated continuous current 100 A at 40 °C, 3-pole, TM210 thermal-magnetic release, interrupting capacity 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 17 kA at 690 V. Includes undervoltage release and two auxiliary switches.

Where can I buy 3VA1110-5ED32-0BC0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request and we will respond with a firm quote.

MPN
3VA1110-5ED32-0BC0